首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >Determination of trace selenium in high purity tellurium by hydride generation atomic fluorescence spectrometry after solid phase extraction of a diaminobenzidine-selenium chelate
【24h】

Determination of trace selenium in high purity tellurium by hydride generation atomic fluorescence spectrometry after solid phase extraction of a diaminobenzidine-selenium chelate

机译:固相萃取二氨基联苯胺-硒螯合物的氢化物发生原子荧光光谱法测定高纯碲中的痕量硒

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Macroporous adsorption resin was used as the sorbent for solid phase extraction and determination of the trace Se content in high purity tellurium prior to hydride generation atomic fluorescence spectrometry analysis. Selenium was converted into an organic Se chelate using 3,3'-diaminobenzidine and was separated from the tellurium matrix by solid phase extraction. The resin was packed as a column for solid phase extraction. Under optimum conditions, trace Se can be quantitatively extracted and the tellurium matrix can be removed. The Se in the eluate was determined by hydride generation atomic fluorescence spectrometry. The limit of detection (3 sigma) of this method was 0.22 ng g(-1) and the relative standard deviation (RSD, n = 5) ranged from 2.0 to 2.5% for the three investigated tellurium samples. The proposed method was successfully applied for the determination of the trace Se content in high purity tellurium samples. (C) 2016 Elsevier B.V. All rights reserved.
机译:大孔吸附树脂用作固相萃取的吸附剂,并在氢化物发生原子荧光光谱分析之前确定高纯度碲中的痕量Se含量。使用3,3'-二氨基联苯胺将硒转化为有机硒螯合物,并通过固相萃取将其与碲基质分离。将该树脂填充为用于固相萃取的柱。在最佳条件下,可以定量提取痕量硒,并可以去除碲基质。洗脱液中的硒通过氢化物发生原子荧光光谱法测定。该方法的检测限(3 sigma)为0.22 ng g(-1),三个被研究的碲样品的相对标准偏差(RSD,n = 5)为2.0%至2.5%。该方法成功地用于高纯度碲样品中痕量硒的测定。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号