首页> 外文期刊>Gait & posture >Test-retest reliability of step counts with the ActivPAL device in common daily activities.
【24h】

Test-retest reliability of step counts with the ActivPAL device in common daily activities.

机译:在日常日常活动中使用ActivPAL设备对步数进行重新测试的可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

The ActivPAL device is a well-established physical activity monitor for assessment of physical activity. AIM: To investigate test-retest reliability of step counts and establish minimal detectable changes (MDC) in step count to account for intra device error over time in various physical activities. METHODS: Healthy participants (n=24, age range, 19-28 years) performed activities on two occasions, 1 week apart, in a laboratory setting; self-paced floor walking, treadmill walking at three different speeds (3.2 km/h, 4.5 km/h and 4.5 km/h with incline), treadmill jogging (8.0 km/h), stair walking and cycling on an exercise bike at three speeds (45 rpm, 60 rpm and 75 rpm). Relative reliability was calculated using intraclass correlation coefficient (ICC) and Spearman correlation. Absolute reliability was assessed using standard error of measurement (SEM) and coefficient of repeatability (CR). RESULTS: The ActivPAL showed high to very high relative reliability for treadmill walking at all speeds and stair walking, while self-paced normal floor walking showed moderate reliability. The absolute reliability was the best for treadmill walking activities, slightly increased for self-paced walking, followed by stair walking and jogging. The use of activity monitors during cycling has been questioned and our results confirm a low absolute and relative reliability. MDC values varied according to the type of activity e.g. treadmill walking 4.5 km/h (10 steps), walking on the floor (45 steps). Data loss in this study (10-13%) was higher than previously reported. CONCLUSIONS: The ActivPAL is reliable for treadmill walking, jogging and self-paced walking. MCD varies according to the activity and should be considered when establishing true change over time.
机译:ActivPAL设备是完善的体育锻炼监测器,用于评估体育锻炼。目的:调查步数的重测可靠性,并在步数中建立最小可检测变化(MDC),以解决各种体育活动中随时间推移的设备内部错误。方法:健康参与者(n = 24,年龄范围,19-28岁)在实验室环境中两次间隔1周进行活动。自定速度的地面行走,跑步机以三种不同的速度行走(分别以3.2 km / h,4.5 km / h和4.5 km / h倾斜),跑步机慢跑(8.0 km / h),楼梯行走和三轮健身车骑行速度(45 rpm,60 rpm和75 rpm)。使用组内相关系数(ICC)和Spearman相关来计算相对可靠性。使用标准测量误差(SEM)和重复性系数(CR)评估绝对可靠性。结果:ActivPAL在所有速度和楼梯行走下均显示出较高至非常高的相对可靠性,而自定速度的正常地面行走则显示出中等可靠性。绝对的可靠性是跑步机步行活动的最佳选择,而对于自定速度的步行则略有提高,其次是楼梯步行和慢跑。自行车运动期间使用活动监视器受到质疑,我们的结果证实绝对和相对可靠性较低。 MDC值根据活动类型而变化,例如跑步机以4.5 km / h(10步)的速度行走,在地板上(45步)行走。这项研究中的数据丢失率(10-13%)高于以前的报告。结论:ActivPAL可在跑步机上行走,慢跑和自定速度的行走中可靠运行。 MCD随活动而变化,并且在确定随时间变化的真正变化时应予以考虑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号