Reliability and minimal detectable difference in multisegment foot kinematics during shod walking and running

机译:行走和跑步过程中多段脚运动学的可靠性和最小可检测差异

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

There has been increased interest recently in measuring kinematics within the foot during gait. While several multisegment foot models have appeared in the literature, the Oxford foot model has been used frequently for both walking and running. Several studies have reported the reliability for the Oxford foot model, but most studies to date have reported reliability for barefoot walking. The purpose of this study was to determine between-day (intra-rater) and within-session (inter-trial) reliability of the modified Oxford foot model during shod walking and running and calculate minimum detectable difference for common variables of interest. Healthy adult male runners participated. Participants ran and walked in the gait laboratory for five trials of each. Three-dimensional gait analysis was conducted and foot and ankle joint angle time series data were calculated. Participants returned for a second gait analysis at least 5 days later. Intraclass correlation coefficients and minimum detectable difference were determined for walking and for running, to indicate both within-session and between-day reliability. Overall, relative variables were more reliable than absolute variables, and within-session reliability was greater than between-day reliability. Between-day intraclass correlation coefficients were comparable to those reported previously for adults walking barefoot. It is an extension in the use of the Oxford foot model to incorporate wearing a shoe while maintaining marker placement directly on the skin for each segment. These reliability data for walking and running will aid in the determination of meaningful differences in studies which use this model during shod gait. (C) 2015 Elsevier B.V. All rights reserved.
机译:最近人们对步态中脚内运动学的测量越来越感兴趣。尽管文献中出现了几种多段脚模型,但牛津脚模型已被频繁用于步行和跑步。几项研究报告了牛津脚模型的可靠性,但迄今为止,大多数研究都报告了赤脚行走的可靠性。这项研究的目的是确定改进的牛津脚模型在短跑和跑步过程中的日间(评估者内)和会话内(试验间)可靠性,并计算感兴趣的常见变量的最小可检测差异。健康的成年男性跑步者参加了比赛。参加者奔跑并在步态实验室中散步,每次进行5次试验。进行了三维步态分析,并计算了脚踝关节角度时间序列数据。参与者至少在5天后返回进行第二次步态分析。确定步行和跑步时的组内相关系数和最小可检测差异,以表明会话内和日间可靠性。总体而言,相对变量比绝对变量更可靠,会话内的可靠性大于日间可靠性。组间日间相关系数与以前报道的赤脚行走成年人的可比性相当。这是对牛津脚模型的使用的扩展,它结合了穿鞋的方式,同时将每个部分的标记直接放置在皮肤上。这些用于步行和跑步的可靠性数据将有助于确定在步态步态中使用该模型的研究中有意义的差异。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号