Kinematic models are commonly used to quantify foot and ankle kinematics, yet no marker sets or models have been proven reliable or accurate when wearing shoes. Further, the minimal detectable difference of a developed model is often not reported. We present a kinematic model that is reliable, accurate and sensitive to describe the kinematics of the foot-shoe complex and lower leg during walking gait. In order to achieve this, a new marker set was established, consisting of 25 markers applied on the shoe and skin surface, which informed a four segment kinematic model of the foot-shoe complex and lower leg. Three independent experiments were conducted to determine the reliability, accuracy and minimal detectable difference of the marker set and model. Inter-rater reliability of marker placement on the shoe was proven to be good to excellent (ICC=0.75-0.98) indicating that markers could be applied reliably between raters. Intra-rater reliability was better for the experienced rater (ICC=0.68-0.99) than the inexperienced rater (ICC=0.38-0.97). The accuracy of marker placement along each axis was 6.7mm for all markers studied. Minimal detectable difference (MDD90) thresholds were defined for each joint; tibiocalcaneal joint - MDD90=2.17-9.36°, tarsometatarsal joint - MDD90=1.03-9.29° and the metatarsophalangeal joint - MDD90=1.75-9.12°. These thresholds proposed are specific for the description of shod motion, and can be used in future research designed at comparing between different footwear.
机译:运动学模型通常用于量化足部和踝部运动学,但没有标记集或模型被证明在穿鞋时可靠或准确。此外,通常不会报告已开发模型的最小可检测差异。我们提出了一种可靠,准确和灵敏的运动学模型来描述步行步态中脚-鞋复合体和小腿的运动学。为了实现这一目标,建立了一个新的标记集,该标记集由25个应用于鞋和皮肤表面的标记组成,为脚-鞋复合体和小腿的四段运动学模型提供了依据。进行了三个独立的实验,以确定标记集和模型的可靠性,准确性和最小可检测差异。事实证明,标记在鞋上的评估者之间的可靠性非常好(ICC = 0.75-0.98),表明标记可以在评估者之间可靠地使用。有经验的评估者(ICC = 0.68-0.99)比没有经验的评估者(ICC = 0.38-0.97)的评估者内部可靠性更好。对于所有研究的标记,沿每个轴放置标记的精度均<6.7mm。为每个关节定义了最小可检测差异(MDD90)阈值;胫骨跟关节-MDD90 = 2.17-9.36°,ta骨关节-MDD90 = 1.03-9.29°和tar趾关节-MDD90 = 1.75-9.12°。提出的这些阈值特定于鞋运动的描述,可用于将来在比较不同鞋类时设计的研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号