Reliability, smallest real difference and concurrent validity of indices computed from GRF components in gait of stroke patients.

机译:由中风患者步态中GRF成分计算得出的指标的可靠性,最小实际差异和并发有效性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We analysed reliability, smallest real difference (SRD) and concurrent validity of indices computed from the ground reaction force (GRF) vertical and fore-aft components in a sample of 56 patients with hemiparesis secondary to stroke. These parameters have been recommended for the assessment of weight-bearing and propulsion. The sample size was calculated based on guidelines for reliability studies and patient levels of impairment ranged from mild to severe. Reliability was assessed by the intraclass correlation coefficient (ICC), SRD was computed as the 95% confidence interval (CI) of the standard error and concurrent validity was assessed using the Spearman correlation coefficient between each index and gait speed, with the latter being used as the criterion standard. Excellent reliability (ICC>0.90) for all indices was achieved by averaging values of three consecutive gait trials. SRD ranged between 5% and 10% of the sample grand mean for vertical GRF-based indices, and between 20% and 40% for fore-aft GRF-based indices. All indices but one showed concurrent validity with walking speed, with correlation coefficients ranging from 0.423 (p<0.01) to 0.834 (p<0.01). Amongst studied indices, the mean value of vertical GRF and the mean value of the propulsive part of the fore-aft component showed the best performance in terms of ICC, SRD and concurrent validity. These appear to be the most appropriate indices to assess weight-bearing and propulsive ability, respectively, in this group.
机译:我们分析了由中风继发偏瘫的56例患者的地面反作用力(GRF)垂直分量和前后分量计算出的指标的可靠性,最小真实差异(SRD)和指标的并发有效性。建议将这些参数用于评估负重和推进力。样本量是根据可靠性研究指南计算的,患者损伤程度从轻度到重度不等。通过组内相关系数(ICC)评估可靠性,计算SRD为标准误差的95%置信区间(CI),并使用每个指标与步态速度之间的Spearman相关系数评估并发有效性,并使用后者作为标准。通过对三个连续步态试验的平均值进行计算,所有指标均具有出色的可靠性(ICC> 0.90)。对于基于GRF的垂直指标,SRD介于样本总体平均值的5%至10%之间,对于基于GRF的前后指标,其SRD介于20%至40%之间。除一项指标外,所有指标均与步行速度并发有效,相关系数范围为0.423(p <0.01)至0.834(p <0.01)。在研究的指标中,垂直GRF的平均值和前-后分量的推进部分的平均值表现出最佳的ICC,SRD和并发有效性。这些似乎分别是评估该组负重和推进能力的最合适指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号