首页> 外文期刊>International Journal of Industrial Ergonomics >On-the-hand measurement methods for assessing effectiveness of anti-vibration gloves
【24h】

On-the-hand measurement methods for assessing effectiveness of anti-vibration gloves

机译:评估防震手套有效性的现有测量方法

获取原文
获取原文并翻译 | 示例
           

摘要

Several technical difficulties have been associated with the current test and evaluation methods for assessing the vibration isolation effectiveness of anti-vibration gloves. The effectiveness of the gloves for specific powered hand tools can be assessed through measurement of acceleration on the head of the third metacarpal or at the wrist. In the present study, the reliability of these on-the-hand measurement methods is evaluated through assessing the vibration transmissibility of gloves while operating chipping hammers. Two different methods, with and without the prior knowledge of tool vibration, for deriving the transmissibility of the gloves are also evaluated. The study used an air bladder glove and a gel-filled glove, two chipping hammers, and feed forces in the 50-200 N range. Six male volunteers were used as test subjects. The transmissibility of the gloves is also estimated using a total vibration transfer function method. The results suggest that the on-the-hand methods offer some unique advantages over the palm adapter method outlined in ISO-10819, but they suffer from poor repeatability when a high degree of tool vibration variability is observed, especially if the tool vibration is not measured and used for the assessment. Glove transmissibility measured at the third metacarpal is more repeatable than that derived from the measurements at the wrist. Reasonably good agreements were observed between the predicted and measured transmissibility values of the air glove. However, the measured transmissibility values for the gel-filled glove suggest that it may perform better than as predicted using the transfer function method.
机译:当前的用于评估防振手套的隔振效果的测试和评估方法存在若干技术难题。可以通过测量第三掌骨或手腕上的加速度来评估特定电动工具的手套的有效性。在本研究中,通过评估操作凿锤时手套的振动传递率来评估这些现有测量方法的可靠性。在有和没有工具振动的先验知识的情况下,还评估了两种不同的方法来得出手套的透射率。这项研究使用了一个气囊手套和一个凝胶手套,两个碎锤,进给力在50-200 N范围内。六名男性志愿者被用作测试对象。手套的透射率也使用总振动传递函数法进行估算。结果表明,与ISO-10819中概述的手掌适配器方法相比,现有方法具有一些独特的优势,但是当观察到高度的工具振动变化时,特别是在没有工具振动的情况下,它们的可重复性很差。测量并用于评估。在第三个掌骨处测量的手套的透射率比从腕部测量得到的手套的透射率更可重复。在预测的和测量的空气手套的透射率值之间观察到合理的良好一致性。但是,测得的凝胶填充手套的透射率值表明它的性能可能好于使用传递函数法预测的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号