首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Two-step separation and determination of inorganic As species in water, soil and sediment samples by implementing two ionic liquids in dispersive liquid-liquid microextraction with electrothermal atomic absorption spectrometry detection
【24h】

Two-step separation and determination of inorganic As species in water, soil and sediment samples by implementing two ionic liquids in dispersive liquid-liquid microextraction with electrothermal atomic absorption spectrometry detection

机译:通过电热原子吸收光谱检测在分散液 - 液微萃取中实施两种离子液体,通过电热原子吸收光谱检测进行两步分离和水,土壤和沉积物样品中无机的测定

获取原文
获取原文并翻译 | 示例
           

摘要

A highly efficient liquid-liquid microextraction method based on two magnetic ionic liquids (MILs) as extraction solvents for the determination of inorganic As species in water, soil and sediment samples, with electrothermal atomic absorption spectrometry detection, was developed. First, As(III) species was separated by chelation with ammonium pyrrolidine dithiocarbamate and then extracted by the MIL trihexyl(tetradecyl)phosphonium hexachlorodisprosiate ([P-6,P-6,P-6,P-14](3)DyCl6). The As(V) species remaining in the aqueous phase was preconcentrated by extraction in the MIL trihexyl(tetradecyl)phosphonium tetrachloroferrate ([P-6,P-6,P-6,P-14]FeCl4) at 2 mol L-1 HCl. The MIL phase containing As(V) was separated by a magnetic rod and diluted in chloroform. Then, an aliquot was injected into the graphite furnace for As determination. Total inorganic As was determined using the MIL [P-6,P-6,P-6,P-14]FeCl4 as the extraction solvent at 0.5 mol L-1 HCl to achieve the same extraction efficiency for both species. The concentration of As(III) was calculated by the difference between total inorganic As and As(V) concentration. An extraction efficiency of 99% for As(V) and an enhancement factor of 35 were obtained with 5 mL of sample. The method detection limits were 17 ng L-1, 0.11 ng g(-1) and 0.13 ng g(-1) for As(V) and 20 ng L-1, 0.13 ng g(-1) and 0.14 ng g(-1) for As(III) in water, soil and sediment samples, respectively. The relative standard deviations for six replicate measurements of 3 mu g L-1 for As(V) and As(III) were 3.1% and 3.9% respectively. The calibration linear range was 0.05-13 mu g L-1. The method was successfully applied for inorganic As species determination in water, soil and sediment samples.
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号