摘要

A selective and simple method for separation and preconcentration of zinc ions was developed by using dispersive liquid-liquid microextraction. Parameters that have an effect on the microextraction efficiency such as volume of extraction and disperser solvent, extraction time, and adding salt were investigated. Under optimum conditions, a preconcentration factor of 250 was obtained. The limit of detection (LOD) obtained under the optimal conditions was 0.09 ng mL−1. The linearity of method was obtained in range of 0.2–50 ng mL−1 with a correlation coefficient (r) of 0.9974. The relative standard deviation for 10 replicate determinations at 1.0 ng mL−1 of zinc was 2.53%. The proposed method was successfully applied to the analysis of zinc in water sample.
机译:通过使用分散液-液微萃取技术,开发了一种选择性,简单的锌离子分离和富集方法。研究了影响微萃取效率的参数,例如萃取量和分散剂的溶剂量,萃取时间和添加盐。在最佳条件下,预浓缩系数为250。在最佳条件下获得的检出限(LOD)为0.09 ng mL -1 。该方法的线性范围为0.2–50 ng mL -1 ,相关系数(r)为0.9974。锌的1.0 ng mL -1 下10次重复测定的相对标准偏差为2.53%。该方法已成功应用于水样中锌的分析。