The purpose of this work was to present body size and tube voltage-dependent equations for optimal selection of image acquisition parameters in guiding clinical X-ray imaging. The dose output of X-ray tubes was expressed as a function of the image acquisition parameters of tube voltage (kVp), tube current–exposure time product (mAs), and body size ( d ). Dose power ( n ) to kVp was determined to be a linear function of body size in an earlier phantom study. Tube voltage-dependent attenuation coefficients of water were used to determine the kVp effect on the depth dose of X-rays from the body’s entrance surface. The new expression for the dose output of X-ray tubes in patients was then employed for image quality and radiation dose optimization, assuming that image quality is a logistic function of the radiation dose to patients. For constant kVp, the percentage of mAs increase for a 1-cm increase in body size d is dependent on the kVp applied. For constant mAs, the percentage of kVp increase for a 1-cm increase in body size is dependent on both body size d and the kVp applied. For constant body size, the percentage of kVp increase should be a fraction of the percentage of decrease in the mAs, where the fraction is dependent on the body size. The improved body size and tube voltage-dependent governing equations for variations in X-ray imaging parameters should be more accurate in guiding optimal selection of the kVp and mAs image acquisition parameters in medical X-ray imaging.
机译:该工作的目的是呈现体尺寸和管电压相关方程,以获得引导临床X射线成像的图像采集参数的最佳选择。 X射线管的剂量输出表示为管电压(KVP),管电流暴露时间产品(MAS)和体尺寸(D)的图像采集参数的函数。将剂量功率(N)达到KVP被确定为在早期的幻像研究中的体尺寸的线性函数。管电压依赖性衰减系数水用于确定来自身体入口表面的深度剂量的kVP效应。然后用于患者X射线管剂量输出的新表达用于图像质量和辐射剂量优化,假设图像质量是对患者的辐射剂量的逻辑功能。对于恒定的KVP,MAS增加到1厘米的体尺寸D的百分比依赖于所施加的KVP。对于恒定的MAS,1厘米的体尺寸增加的KVP增加百分比取决于体型D和kVp施加的kvp。对于恒定体积,KVP增加的百分比应该是MAS减少百分比的一小部分,其中馏分取决于体尺寸。用于X射线成像参数的变化的改进的体尺寸和管电压依赖性控制方程应该更准确地引导医疗X射线成像中的KVP和MAS图像采集参数的最佳选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号