Background:Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan.Objective:An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established.Materials and Methods:The analytes were separated on a Shiseido C18 column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm.Results:Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R2 > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%.Conclusion:The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea.
机译:背景:蒿是一种在东亚包括中国,韩国和日本治疗湿疹和黄疸的传统草药。目的:使用高效液相色谱-二极管阵列紫外/可见检测器和液相色谱法进行准确而灵敏的分析方法-质谱法同时测定菜中的三种植物甾醇,菜油甾醇,豆甾醇和豆甾醇。材料与方法:在资生堂C18色谱柱(5μm,4.6 mm ID×250 mm)上分离分析物。洗脱0.1%三氟乙酸和乙腈。流速为1 mL / min,检测波长分别为205和254 nm。结果:验证了该方法的线性,精密度和准确性。校准曲线显示出良好的线性(R2> 0.9994)。检测限和定量限分别在0.55-7.07μg/ mL和1.67-21.44μg/ mL范围内。并且,日内和日间精确度的相对标准偏差<2.93%。回收率在90.03–104.91%之间。结论:该方法已成功地用于香菜油中菜油甾醇,豆甾醇和豆甾醇的质量控制分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号