The performance of laser-induced breakdown spectroscopy for quantitative analysis of wear metals in oils has been evaluated in this work with a specific ablation configuration of a thin layer of oil covering the polished surface of a pure aluminum target. A set of reference samples containing 12 metallic elements (Ag, Al, Cr, Cu, Fe, Mg, Na, Ni, Pb, Si, Sn, and Ti) was prepared by dilution with a 75 cSt hydrocarbon base oil for the concentration range from 20 to 500 μg/g. Calibration curves were therefore established for these elements with an echelle spectrometer and then with a Czemy-Turner spectrometer. The obtained results show first high linearity of the calibration curves established with the two types of spectrometer, the determination coefficient, R~2, of all the calibration curves are superior to 0.99. The limits of detection (LoDs) with an echelle spectrometer vary in the range from 0.29 to about 10 μg/g with an average value of 6.02 pg/g for the 9 elements (Al, Na and Pb excluded). The use of a Czerny-Turner spectrometer reduces furthermore the LoDs to the range from 0.24 to about 10 μg/g with an average value over the 10 elements (Al and Na excluded) of 4.04 μg/g. In addition, the LoDs for the 3 elements (Mg, Cu and Ag) are determined lower than ug/g, i.e. in the sub-ppm level. Comparison with the previously published data shows moreover the efficiency of the introduced ablation configuration as one of the most suitable methods for highly sensitive and precise wear metal analysis in oils.
机译:在这项工作中,采用激光诱导击穿光谱法对油中的磨损金属进行定量分析的性能,通过覆盖纯铝靶材抛光表面的油薄层的特定烧蚀结构进行了评估。通过用75 cSt烃基油稀释至浓度范围,制备了一组包含12种金属元素(Ag,Al,Cr,Cu,Fe,Mg,Na,Ni,Pb,Si,Sn和Ti)的参考样品。 20至500μg/ g。因此,使用echelle光谱仪,然后使用Czemy-Turner光谱仪,为这些元素建立了校准曲线。获得的结果表明,用两种类型的光谱仪建立的校准曲线具有较高的线性,所有校准曲线的测定系数R〜2均优于0.99。阶梯质谱仪的检出限(LoDs)在0.29至约10μg/ g的范围内变化,这9种元素(不包括Al,Na和Pb)的平均值为6.02 pg / g。 Czerny-Turner光谱仪的使用进一步将LoD降低到0.24至约10μg/ g的范围内,这10种元素(Al和Na除外)的平均值为4.04μg/ g。另外,确定了三种元素(Mg,Cu和Ag)的LoD低于ug / g,即亚ppm级。与以前发表的数据进行比较还表明,引入的烧蚀配置的效率是用于油中高灵敏度和精确的磨损金属分析的最合适方法之一。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号