This article presents a test rig to measure the dynamic heat transfer coefficient of the refrigerant R-134a in a small-diameter horizontal pipe. The experiment layout is basically a cooling cycle. The basic components are a receiver tank filled with R-134a, a pump, an evaporator pipe, and a condenser. The evaporator pipe made out of copper is the main element. Thermocouples, pressure sensors, and a mass flow sensor provide the information necessary to determine the heat transfer coefficient of the horizontal pipe. In addition to the experimental investigations, a numerical model is created. The results are compared with the test rig results to validate the numerical model.
机译:本文介绍了一种用于测量小直径水平管道中制冷剂R-134a的动态传热系数的试验台。实验布局基本上是一个冷却周期。基本组件是装有R-134a的储液罐,泵,蒸发器管和冷凝器。由铜制成的蒸发器管是主要元素。热电偶,压力传感器和质量流量传感器提供确定水平管道传热系数所需的信息。除了实验研究之外,还创建了一个数值模型。将结果与试验台结果进行比较,以验证数值模型。