OBJECTIVES: The diagnostic accuracy of direct digital radiography for the detection of small, experimentally made, periapical lesions was compared with that of E speed film. The high- and low-contrast resolutions of the imaging systems were also compared. STUDY DESIGN: The high-contrast resolution was evaluated with a line pair plate. The low-contrast resolution was determined with a contrast-detail plexiglass phantom. To evaluate the diagnostic accuracy, the periapical region of dry human mandibles was examined. Receiver operating characteristic based on the readings of seven observers were generated. RESULTS: The high-contrast resolution of the digital system was inferior, but the low-contrast resolution was comparable to that of E-speed film. For diagnostic accuracy no significant difference was seen between the areas under the receiver operating characteristic curves. CONCLUSIONS: The quality of the direct digital images is comparable to that of E-speed film for the detection of periapical bone lesions.
机译:目的:将直接数字射线照相术对检测出的小,实验性根尖周病变的诊断准确性与E速度胶片进行比较。还比较了成像系统的高对比度和低对比度分辨率。研究设计:用线对板评估高对比度分辨率。低对比度的分辨率是由对比细节有机玻璃体模确定的。为了评估诊断准确性,检查了干燥的人类下颌骨的根尖区域。根据七个观察者的读数,得出接收器的工作特性。结果:数字系统的高对比度分辨率较差,但低对比度分辨率可与E-speed胶片相媲美。对于诊断准确性,在接收器工作特性曲线下方的区域之间没有发现显着差异。结论:直接数字图像的质量与E-speed胶片在根尖周骨病变检测中的质量相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号