首页> 外文期刊>Retina >COMPARISON OF THE ORIGINAL AMSLER GRID WITH THE MODIFIED AMSLER GRID: Result for Patients With Age-Related Macular Degeneration.
【24h】

COMPARISON OF THE ORIGINAL AMSLER GRID WITH THE MODIFIED AMSLER GRID: Result for Patients With Age-Related Macular Degeneration.

机译:原始Amsler网格与改良Amsler网格的比较:与年龄相关的黄斑变性患者的结果。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE:: To compare the sensitivity of the original Amsler grid presenting white lines on a black background with that of the modified standard version of the grid presenting black lines on a white background in the detection of visual disturbances. PATIENTS AND METHODS:: One hundred eighty-two patients (182 eyes) with dry and exudative age-related macular degeneration and a history of metamorphopsia were instructed to use an Amsler grid. None of the patients were familiar with an Amsler grid or had used it previously. If the disease was present in both eyes, one eye was chosen as the study eye by randomization. Both grid types were presented and used for documentation of central visual field changes. The sequence of presentation of the respective grid was also chosen by randomization. Original Amsler grid questions were used for grading ("metamorphomas" and "scotomas"). Visual acuity of patients ranged from 0.1 to 0.7. Subgroup analysis was performed based on the visual acuity levels. RESULTS:: For the overall study population, the original Amsler grid provided significantly better results than the modified version. Evaluation of data for the different subgroups showed no significant difference between patients with visual acuity ranging from 0.1 to 0.3. For patients with visual acuity of 0.5 or better, the original Amsler grid was significantly more informative and reliable than the modified version. CONCLUSION:: For patients with macular diseases, use of the original Amsler grid (white lines on a black background) should be recommended. This is particularly important for patients with visual acuity of 0.5 or better.
机译:目的:为了比较检测视觉障碍时,在黑色背景上呈现白线的原始Amsler网格与在白色背景上呈现黑线的网格的标准版的灵敏度。患者和方法:指示182例干性和渗出性年龄相关性黄斑变性并有变态史的患者使用Amsler网格。没有患者熟悉或曾经使用过Amsler网格。如果该疾病在两只眼睛中都存在,则通过随机选择一只眼睛作为研究眼睛。提出了两种栅格类型,并用于记录中心视野变化。还通过随机选择各个网格的呈现顺序。原始的Amsler网格问题用于评分(“变形金刚”和“ scotomas”)。患者的视力范围从0.1到0.7。根据视敏度水平进行亚组分析。结果:对于整个研究人群,原始的Amsler网格提供的结果明显优于修改后的网格。对不同亚组的数据评估显示,视敏度在0.1至0.3之间的患者之间无显着差异。对于视力为0.5或更高的患者,原始的Amsler网格比修改后的版本具有更多的信息性和可靠性。结论:对于黄斑疾病患者,应建议使用原始的Amsler网格(黑色背景上的白线)。这对于视力为0.5或更高的患者尤其重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号