Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors.

机译:三种用于治疗脑部和头部和颈部肿瘤的热塑性面膜的安装精度的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Setup accuracy is an important factor influencing the definition of the planning target volume (PTV). The purpose of this study was to compare the setup accuracy of three different thermoplastic masks used for immobilization of patients with brain or head and neck tumors. MATERIALS AND METHODS: Thirty patients with brain or head and neck tumors were consecutively assigned to one of three different thermoplastic masks (Posifix): head mask with three fixation points (3 FP, ten patients), head and shoulder mask with four fixation points (4 FP, ten patients), head and shoulder mask with five fixation points (5 FP, four fixations plus an additional one on the top of head, ten patients). Once a week, during the session with a 6 MV linac (Elekta), orthogonal (antero-posterior and lateral) portal images were acquired for three fictitious isocenters placed during the simulation at the level of the head, the neck and the shoulders. Portal images and digitized simulator films were compared using the PIPS pro software, and displacements in antero-posterior (A-P), cranio-caudal (C-C) and medio-lateral (M-L) directions were calculated. From these displacements, 2D or 3D errors were also calculated. RESULTS: A total of 915 portal images were obtained, of which 98% could be analyzed. For the whole population, total displacements reached a standard deviation (SD) of 2.2 mm at the level of the head and the neck. Systematic and random displacements were in the same order of magnitude and reached a SD of 1.8 mm. Patient setup was slightly worse at the shoulder level with a total displacement of 2.8 mm (1 SD) for both the C-C and the M-L directions. There again, the systematic and the random components were in the same order of magnitude below 2.4 mm (+/-SD). For isocenters in the head and in the neck, there was no substantial difference in the setup deviation between the three masks. The setup reproducibility was found to be significantly worse (P=0.01) at the level of the shoulders with the 3 FP mask. For the 2D random error, 1 SD of 2.3 mm was observed compared to 0.8 and 1.2 mm for the 4 and 5 FP masks, respectively. Lastly, 90% of the 3D total deviations were below 4.5 mm for the head and the neck. In the shoulder region, 90% of the 2D total deviations were below 5.5 mm. CONCLUSION: Thermoplastic masks provide an accurate patient immobilization. At the shoulder level, setup variations are reduced when 4 or 5 FP masks are used. These data could be used for the assessment of margins for the PTV.
机译:目的:设置精度是影响计划目标体积(PTV)定义的重要因素。这项研究的目的是比较三种固定在脑部或头颈部肿瘤患者身上的热塑性面膜的设置精度。材料与方法:将30例患有脑部或头颈部肿瘤的患者连续分配到三种不同的热塑性面罩(Posifix)中的一种:具有三个固定点的头罩(3 FP,十个患者),具有四个固定点的头肩面罩( 4个FP,十个病人),头和肩面罩有五个固定点(5个FP,四个固定点,再加上一个在头顶的固定物,十个病人)。每周一次,在使用6 MV直线加速器(Elekta)的训练期间,在模拟过程中在头部,颈部和肩膀的水平放置的三个虚拟等角点获取正交(前后和横向)门图像。使用PIPS pro软件比较门户图像和数字化模拟器胶片,并计算前后(A-P),颅尾(C-C)和中外侧(M-L)方向的位移。根据这些位移,还可以计算2D或3D误差。结果:共获得915张门图像,其中98%可以被分析。对于整个人群,总位移在头部和颈部的水平处达到2.2毫米的标准偏差(SD)。系统位移和随机位移的数量级相同,SD达到1.8 mm。在C-C和M-L方向上,患者的肩部水平设置都稍差一些,总位移为2.8 mm(1 SD)。再次,系统和随机分量在2.4毫米(+/- SD)以下处于相同的数量级。对于头部和颈部的等中心点,三个面罩之间的设置偏差没有实质性差异。发现在使用3 FP面罩的肩膀水平上,安装可重复性明显较差(P = 0.01)。对于2D随机误差,观察到1 SD为2.3 mm,而4个和5个FP掩模分别为0.8和1.2 mm。最后,头部和颈部3D总偏差的90%低于4.5毫米。在肩部区域,二维总偏差的90%在5.5毫米以下。结论:热塑口罩可为患者提供精确的固定。在肩部,使用4或5个FP口罩时,可以减少设置变化。这些数据可用于评估PTV的利润。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号