Application of a test package in an intercomparison of the photon dose calculation performance of treatment planning systems used in a clinical setting.

机译:测试包在临床环境中使用的治疗计划系统的光子剂量计算性能的比较中的应用。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND PURPOSE: Testing the performance of treatment planning systems by using the AAPM Task Group 23 test package is a useful approach, but has its limitations. To be able to include technical developments, such as the asymmetric collimator, it was decided to remeasure the AAPM data set on more modern radiotherapy equipment, to extend the test geometries, and to evaluate the use of the new package. MATERIALS AND METHODS: A coherent set of beam data of 6, 10 and 18 MV photon beams was measured on two modern linear accelerators. These data served as input data in seven commercially available treatment planning systems, which were clinically in use in different radiotherapy departments. Next, a test package was measured which included a missing tissue geometry and fields with asymmetrical collimator setting, with and without a wedge. RESULTS: The absolute dose prediction from the different treatment planning systems in which the measured beam data were entered, was compared for all test points with the results of direct measurements. The criteria of acceptability were exceeded by some systems in cases of irregular field geometry and missing tissue geometry. The majority of the systems had difficulties with accurate dose calculation for asymmetrically wedged fields. CONCLUSIONS: The application of the new test package did not introduce insuperable difficulties and was highly appreciated by the participating centres. Most systems performed reasonably well for the majority of the beam geometries, with the exception of asymmetrically wedged beams. The extended test package is available for other users or user groups for the purpose of commissioning new treatment planning systems, or new releases of existing systems.
机译:背景与目的:通过使用AAPM Task Group 23测试包测试治疗计划系统的性能是一种有用的方法,但有其局限性。为了能够包括非对称准直仪等技术发展,决定重新测量更多现代放射治疗设备上的AAPM数据集,以扩展测试几何形状,并评估新包装的使用。材料与方法:在两个现代的线性加速器上测量了一组相干的6、10和18 MV光子束数据。这些数据在七个市售治疗计划系统中用作输入数据,这些系统在临床上已在不同的放射治疗部门中使用。接下来,测量了一个测试包,其中包括缺少的组织几何形状以及具有和不具有楔形物的具有非对称准直仪设置的视野。结果:将来自不同治疗计划系统的绝对剂量预测值与直接测量的结果进行了比较,其中输入了测量的射束数据的不同治疗计划系统均在其中。在某些领域中,如果几何形状不规则且组织几何形状缺失,则某些系统会超出可接受标准。对于不对称楔形场,大多数系统都难以准确计算剂量。结论:新测试包的应用没有引入不可克服的困难,并得到了参与中心的高度赞赏。除不对称楔形光束外,大多数系统对于大多数光束几何形状都表现良好。扩展的测试包可用于其他用户或用户组,以用于调试新的治疗计划系统或现有系统的新版本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号