【24h】

Dosimetric characteristics of 6 and 10MV unflattened photon beams.

机译:6和10MV未展平光子束的剂量特性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To determine dosimetric properties of unflattened megavoltage photon beams. MATERIALS AND METHODS: Dosimetric data including depth dose, profiles, output factors and phantom scatter factors from three different beam qualities provided by Elekta Precise linacs, operated with and without flattening filter were examined. Additional measurements of leaf transmission, leakage radiation and surface dose were performed. In flattening filter free (FFF) mode a 6-mm thick copper filter was placed into the beam to stabilize it. RESULTS: Depths of dose maxima for flattened and unflattened beams did not deviate by more than 2mm and penumbral widths agreed within 1mm. In FFF mode the collimator exchange effect was found to be on average 0.3% for rectangular fields. Between maximum and minimum field size head scatter factors of unflattened beams showed on average 40% and 56% less variation for 6 and 10MV beams than conventional beams. Phantom scatter factors for FFF beams differed up to 4% from the published reference data. For field sizes smaller than 15cm, surface doses relative to the dose at d(max) increased for unflattened beams with maximum differences of 7% at 6MV and 25% at 10MV for a 5x5cm(2) field. For a 30x30cm(2) field, relative surface dose decreased by about 10% for FFF beams. Leaf transmission on the central axis was 0.3% and 0.4% lower for unflattened 6 and 10MV beams, respectively. Leakage radiation was reduced by 52% for 6MV and by 65% for 10MV unflattened beams. CONCLUSIONS: The results of the study were independently confirmed at two radiotherapy centres. Phantom scatter reference data need to be reconsidered for medical accelerators operated without a flattening filter.
机译:目的:确定未展平的兆伏光子束的剂量学性质。材料与方法:检查了剂量数据,包括深度剂量,轮廓,输出因子和幻影散射因子,这些数据来自Elekta Precise直线加速器提供的三种不同光束质量,使用和不使用平坦滤波器。进行了叶片透射率,泄漏辐射和表面剂量的其他测量。在无滤波器的扁平化(FFF)模式下,将6毫米厚的铜滤波器放入光束中以使其稳定。结果:平坦和未平坦光束的最大剂量深度偏差不超过2mm,半影宽度在1mm以内。在FFF模式下,发现矩形场的准直器交换效果平均为0.3%。在最大和最小场尺寸之间,未展平光束的头部散射因子显示,与传统光束相比,6和10MV光束的平均变化小40%和56%。 FFF光束的幻像散射因子与已发布的参考数据相差高达4%。对于小于15cm的场,对于未展平的光束,表面剂量相对于d(max)处的剂量增加,对于5x5cm(2)场,在6MV处最大差异为7%,在10MV处最大差异为25%。对于30x30cm(2)场,FFF光束的相对表面剂量减少了约10%。对于未展平的6和10MV光束,中心轴上的叶片透射率分别降低0.3%和0.4%。对于6MV,泄漏辐射减少了52%,对于10MV未展平的光束,减少了65%。结论:研究结果在两个放疗中心独立确认。对于不带平整滤波器的医疗加速器,需要重新考虑幻影散布参考数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号