BACKGROUND AND PURPOSE: A multi-centre clinical trial for prostate cancer patients provided an opportunity to introduce conformal radiotherapy with dose escalation. To verify adequate treatment accuracy prior to patient recruitment, centres submitted details of a set-up accuracy study (SUAS). We report the results of the SUAS, the variation in clinical practice and the strategies used to help centres improve treatment accuracy. MATERIALS AND METHODS: The SUAS required each of the 24 participating centres to collect data on at least 10 pelvic patients imaged on a minimum of 20 occasions. Software was provided for data collection and analysis. Support to centres was provided through educational lectures, the trial quality assurance team and an information booklet. RESULTS: Only two centres had recently carried out a SUAS prior to the trial opening. Systematic errors were generally smaller than those previously reported in the literature. The questionnaire identified many differences in patient set-up protocols. As a result of participating in this QA activity more than 65% of centres improved their treatment delivery accuracy. CONCLUSIONS: Conducting a pre-trial SUAS has led to improvement in treatment delivery accuracy in many centres. Treatment techniques and set-up accuracy varied greatly, demonstrating a need to ensure an on-going awareness for such studies in future trials and with the introduction of dose escalation or new technologies.
机译:背景与目的:一项针对前列腺癌患者的多中心临床试验提供了一个机会,可以随着剂量的增加采用保形放射疗法。为了在招募患者之前验证适当的治疗准确性,各中心提交了设置准确性研究(SUAS)的详细信息。我们报告了SUAS的结果,临床实践的变化以及用于帮助中心提高治疗准确性的策略。材料与方法:SUAS要求24个参与中心中的每一个收集至少20次成像的至少10名骨盆患者的数据。提供了用于数据收集和分析的软件。通过教育讲座,审判质量保证小组和信息手册为中心提供了支持。结果:只有两个中心在试验开放之前最近进行了SUAS。系统误差通常小于文献中先前报道的误差。该调查表确定了患者设置方案中的许多差异。参加此QA活动的结果是,超过65%的中心提高了其治疗的准确性。结论:进行预审SUAS可以改善许多中心的治疗交付准确性。治疗技术和设置准确性差异很大,这表明需要确保在未来的试验中不断了解此类研究,并需要逐步增加剂量或采用新技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号