【24h】

Anatomy based inverse planning in HDR prostate brachytherapy.

机译:HDR前列腺近距离放射治疗中基于解剖学的逆向计划。

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study is to evaluate anatomy based inverse planning as implemented in PLATO BPS 14.2 for planning of HDR prostate implants. Six patients were analysed. The dose distributions were optimized using geometric optimization followed by graphical optimization (GO), anatomy based inverse planning or standard inverse optimization (SIO), tuned inverse optimization (TIO) and tuned inverse optimization followed by graphical optimization (GOTIO). The mean target coverage was 93+/-4%, 53+/-11%, 74+/-8%, 90+/-3%, respectively, for GO, SIO, TIO and GOTIO. The conformal index COIN was 0.74+/-0.02, 0.43+/-0.15 and 0.77+/-0.07, respectively, for GO, SIO and GOTIO. Improved dose homogeneity was found when comparing GOTIO with GO.
机译:这项研究的目的是评估在PLATO BPS 14.2中实施的用于HDR前列腺植入物计划的基于解剖学的反向计划。分析了六名患者。使用几何优化,图形优化(GO),基于解剖学的逆规划或标准逆优化(SIO),调谐逆优化(TIO)和调谐逆优化然后图形优化(GOTIO)对剂量分布进行优化。 GO,SIO,TIO和GOTIO的平均目标覆盖率分别为93 +/- 4%,53 +/- 11%,74 +/- 8%,90 +/- 3%。 GO,SIO和GOTIO的保形指数COIN分别为0.74 +/- 0.02、0.43 +/- 0.15和0.77 +/- 0.07。比较GOTIO和GO时,发现剂量均匀性得到改善。