Quality of permanent prostate implants using automated delivery with seedSelectrontrade mark versus manual insertion of RAPID Strandstrade mark.

机译:相对于手动插入RAPID Strandstrade商标,使用带有seedSelectrontrade商标的自动递送的永久前列腺植入物的质量。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND PURPOSE: To compare the quality of manually inserted RAPID Strand implants with automatically inserted selectSeed implants using volumetric and dosimetric parameters. PATIENTS AND METHODS: Patients with T1 to T2 prostate carcinoma were treated with brachytherapy. The (125)I seeds were implanted in the prostate in three different ways: manual insertion of RAPID Strands (R); insertion of selectSeeds using the seedSelectron (S); a combination of both techniques: manual insertion of RAPID Strands in the left half of the prostate and insertion of selectSeeds with the seedSelectron in the right half of the prostate (RS). The comparison is based on implant and target specific parameters. The implant specific parameters, V(100), homogeneity index (HI), and natural dose ratio (NDR), were determined at the time of implantation and four weeks later. MR images taken four weeks after the implantation were used for the calculation of the target specific parameters: D(90), HI, external index (EI), and conformation number (CN). RESULTS: We found no significant difference between the groups of implants (R, S, RS) for the implant specific parameters V(100), HI, and NDR at t(0) and neither at t(4w). For each group, the V(100) values decreased significantly with time between t(0) and t(4w). The target specific parameters D(90), HI, EI and CN were not significantly different between the groups. For the group of patients with both RAPID Strands and selectSeeds, we found a significant difference in D(90) between both halves of the prostate. CONCLUSIONS: The dosimetry parameters of a newly introduced implant technique using an automatic seed afterloader were not significantly different from the parameters of a manual insertion technique using RAPID Strands. Since either technique has its advantages and disadvantages regarding seed migration, physics quality assurance, efficiency, logistics, and ease of use, it was decided to use both techniques and to continue evaluations.
机译:背景与目的:使用体积和剂量参数,比较手动插入的RAPID Strand植入物与自动插入的selectSeed植入物的质量。患者与方法:T1至T2前列腺癌患者接受近距离放射治疗。将(125)I种子以三种不同方式植入前列腺中:手动插入RAPID Strands(R);将RAPI​​D Strands(R)插入。使用seedSelectron(S)插入selectSeeds;两种技术的组合:在前列腺的左半部手动插入RAPID链,在前列腺的右半部(RS)插入带有种子选择子的selectSeeds。比较是基于植入物和目标特定参数。植入时和四个星期后确定植入物的特定参数V(100),均一性指数(HI)和自然剂量比(NDR)。植入后四周拍摄的MR图像用于计算目标特定参数:D(90),HI,外部指数(EI)和构象数(CN)。结果:我们发现在植入物的特定参数V(100),HI和NDR在t(0)和t(4w)时,植入物组(R,S,RS)之间没有显着差异。对于每组,V(100)值都在t(0)和t(4w)之间随时间显着下降。两组之间的目标特定参数D(90),HI,EI和CN没有显着差异。对于同时具有RAPID链和selectSeeds的患者,我们发现前列腺的两半之间的D(90)有显着差异。结论:使用自动种子后装载器的新引入的植入技术的剂量学参数与使用RAPID钢绞线的手动插入技术的参数没有显着差异。由于这两种技术在种子迁移,物理质量保证,效率,物流和易用性方面都有其优缺点,因此决定同时使用这两种技术并继续进行评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号