BACKGROUND AND PURPOSE: Although intensity modulated radiotherapy (IMRT) is a step forward in comparison to conventional, static beam delivery, quality assurance is more complex and labour intensive, demanding detailed two-dimensional dosimetric verification. Regardless of the technique used for measuring the dose distribution, what is essential to the implementation of routine verification of IMRT fields is the efficient and accurate comparison of the measured versus desired dose distribution. In order to achieve a fast, yet accurate quantitative measure of the correspondence between measured and calculated dose, the theoretical concept of the gamma evaluation method presented by Low et al. (Med. Phys., 25 (1998) 656) was converted into a calculation algorithm, taking into account practical considerations related to the discrete nature of the data.MATERIALS AND METHODS: A filter cascade of multiple levels was designed to obtain fast and accurate comparison of the two dose distributions under evaluation. The actual comparison consists of classification into accepted or rejected datapoints with respect to user-defined acceptance criteria (dose difference and distance to agreement). The presented algorithm was tested on dosimetric images calculated and/or acquired by means of a liquid filled portal imaging device during the course of intensity modulated treatments of prostate cancer, including pre-treatment verification as well as verification during treatment. To assess its ability to intercept possible errors in dose delivery, clinically relevant errors were deliberately introduced into the dose distributions.RESULTS: The developed gamma filter method proves successful in the efficient comparison of calculated versus measured IMRT dose distribution. Secondly, intercomparison of dosimetric images acquired during different treatment sessions illustrate its potential to highlight variations in the dosimetric images. The simulated errors were unmistakably intercepted.CONCLUSIONS: The readily obtained gamma evaluation images are an easy tool for quality control of IMRT fields. To reduce the artefacts related to the discrete nature and limited resolution of the data, a fast and accurate filter cascade was developed, offering the possibility to use the gamma method for day to day evaluation of patient dosimetric portal images with or without comparison to a predicted portal dose distribution.
机译:背景与目的:尽管与传统的静态束传输相比,强度调制放射疗法(IMRT)向前迈进了一步,但质量保证更为复杂且劳动强度大,需要详细的二维剂量学验证。不管用于测量剂量分布的技术如何,对IMRT场进行常规验证所必需的是,对测量的剂量分布与所需的剂量分布进行有效而准确的比较。为了快速而准确地定量测量和计算的剂量之间的对应关系,Low等人提出了伽马评估方法的理论概念。 (Med。Phys。,25(1998)656)被转换为一种计算算法,同时考虑了与数据离散性相关的实际考虑。材料与方法:设计了多级滤波器级联以获得快速和准确比较评估中的两种剂量分布。实际比较包括根据用户定义的接受标准(剂量差异和达成协议的距离)将接受或拒绝的数据点分类。在前列腺癌的强度调节治疗过程中,通过充液门成像设备计算和/或获取的剂量图像上测试了所提出的算法,包括治疗前的验证以及治疗期间的验证。为了评估其拦截剂量传递中可能出现的错误的能力,特意将与临床相关的错误引入剂量分布中。结果:改进的伽马滤波方法在有效比较计算的和测量的IMRT剂量分布方面证明是成功的。其次,在不同治疗阶段获得的剂量图像的相互比较说明了其突出剂量图像变化的潜力。结论:容易获得的伽马评估图像是IMRT场质量控制的简便工具。为了减少与数据的离散性质和有限分辨率有关的伪像,开发了一种快速而准确的过滤器级联,提供了使用伽马方法对患者剂量学门脉图像进行日常评估的可能性,无论是否与预测值进行比较门剂量分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号