The evaluation of the range of motion (ROM) and static posture in the cervical spine are important in physical examination. Despite offering dynamic assessment without radiation, the video-based motion analysis system has not yet been applied to measure the cervical segmental movements. The purposes of this study were to develop a neck model to differentiate the movements and posture between upper and lower cervical spine, and to examine the reliability of measuring cervical motion with surface markers and the aid of videofluoroscopy. Sixteen healthy adult subjects (eight males and eight females) participated in this study. Ten surface markers were used to estimate the discrepancies in cervical vertebral angles compared with corresponding bony landmarks throughout the ROM. The average intraclass correlation coefficients (ICCs) of the paired vertebral angles between surface markers and bony landmarks ranged from 0.844 to 0.975 and the mean absolute difference (MAD) averaged 2.96 degrees. Our results indicate high consistency between surface markers and bony landmarks throughout the cervical movements. The mean upper (C0-C2) and lower (C2-C7) cervical joint angles in the neutral position were 18.59+/-4.33 degrees and 23.98+/-6.15 degrees, respectively. Furthermore, the reliability of the digitizing procedure within raters (ICC=0.850-0.999; MAD=0.58-2.42 degrees) and between raters (ICC=0.759-0.988; MAD=0.59-2.66 degrees) suggests that the neck motion analysis model is a feasible method for investigating static neck posture or dynamic motion between upper and lower cervical spine.
机译:颈椎的运动范围(ROM)和静态姿势的评估对于身体检查很重要。尽管提供了无辐射的动态评估,但基于视频的运动分析系统尚未应用于测量颈段运动。这项研究的目的是建立一个颈部模型,以区分上下颈椎之间的运动和姿势,并检验使用表面标志物和借助电子荧光透视术测量颈椎运动的可靠性。十六名健康成人受试者(八名男性和八名女性)参加了这项研究。与整个ROM中相应的骨标志相比,使用十个表面标记来估计颈椎角差异。表面标记和骨标志之间的成对椎骨角度的平均类内相关系数(ICC)在0.844至0.975之间,平均绝对差(MAD)平均为2.96度。我们的结果表明在整个颈椎运动过程中,表面标记和骨标志之间具有高度一致性。在中立位置的上颈平均关节角度(C0-C2)和下颈平均角度(C2-C7)分别为18.59 +/- 4.33度和23.98 +/- 6.15度。此外,评估者内部(ICC = 0.850-0.999; MAD = 0.58-2.42度)和评估者之间(ICC = 0.759-0.988; MAD = 0.59-2.66度)的数字化程序的可靠性表明,颈部运动分析模型是一种研究上下颈椎之间静态颈部姿势或动态运动的一种可行方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号