Accurate and easy-to-use measurement tools are required to evaluate the effect of treatments on patient activity. Comfortable device placement and fixation are important for patient compliance. The aim of this study was the evaluation of the accuracy of an accelerometer at different placements and slow velocities. Methods: A total of 43 healthy volunteers were included for a literature-based treadmill protocol using five accelerometer positions; a subset of 18 volunteers performed an extended treadmill protocol with velocities between 0.1 and 2.6. m/s and finally stair climbing. Results: An alternative accelerometer position at the anterolateral aspect of the middle shank did measure steps more accurately than at the manufacturer suggested position, especially during slow velocities. Participants preferred the alternative placement at the shank. The accuracy of different accelerometer positions was excellent at velocities between 1.0 and 2.2. m/s. During slow velocities below 1.0. m/s steps were recorded less accurately. Accepting an error of five percent, the accelerometer recorded steps accurately from 0.5. m/s at the alternative placement and from 0.8. m/s at the manufacturer suggested placement. Stair climbing was not recorded accurately by any accelerometer position. Conclusion: For measuring step number during slow velocities, the alternative position should be favoured. Stair climbing was not recorded accurately by any tested placement.
机译:需要精确且易于使用的测量工具来评估治疗对患者活动的影响。舒适的设备放置和固定对于患者依从性很重要。这项研究的目的是评估加速度计在不同位置和缓慢速度下的准确性。方法:总共43名健康志愿者接受了基于文献的跑步机方案,使用了五个加速度计位置。 18名志愿者的子集执行了速度在0.1到2.6之间的扩展跑步机方案。 m / s,最后爬楼梯。结果:在中柄的前外侧,加速度计的替代位置确实比制造商建议的位置更准确地测量步长,尤其是在速度较慢的情况下。参与者更喜欢在小腿上进行其他放置。在1.0和2.2之间的速度下,不同加速度计位置的精度非常好。多发性硬化症。在低于1.0的缓慢速度下。 m / s步数记录得不太准确。接受5%的误差后,加速度计记录的步距精确到0.5。替代位置的m / s,从0.8开始。制造商建议的放置速度m / s。任何加速度计位置都无法准确记录楼梯爬升的情况。结论:为了在慢速下测量步数,应该选择替代位置。任何经过测试的位置均未准确记录爬楼梯的情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号