Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo.

机译:在体内测得的步态和切割运动中,皮肤运动伪影对膝盖运动学的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

Eight healthy male subjects had intra-cortical bone-pins inserted into the proximal tibia and distal femur. Three reflective markers were attached to each bone-pin and four reflective markers were mounted on the skin of the tibia and thigh, respectively. Roentgen-stereophotogrammetric analysis (RSA) was used to determine the anatomical reference frame of the tibia and femur. Knee joint motion was recorded during walking and cutting using infrared cameras sampling at 120Hz. The kinematics derived from the bone-pin markers were compared with that of the skin-markers. Average rotational errors of up to 4.4 degrees and 13.1 degrees and translational errors of up to 13.0 and 16.1mm were noted for the walk and cut, respectively. Although skin-marker derived kinematics could provide repeatable results this was not representative of the motion of the underlying bones. A standard error of measurement is proposed for the reporting of 3D knee joint kinematics.
机译:八名健康男性受试者的皮质内骨钉插入胫骨近端和股骨远端。将三个反光标记贴在每个骨钉上,并将四个反光标记分别贴在胫骨和大腿的皮肤上。使用伦琴立体摄影测量分析(RSA)来确定胫骨和股骨的解剖参考框架。使用120 Hz采样的红外热像仪记录步行和切割过程中的膝关节运动。将源自骨钉标记的运动学与皮肤标记的运动学进行了比较。行走和切割的平均旋转误差分别为4.4度和13.1度,平移误差分别为13.0和16.1mm。尽管从皮肤标记获得的运动学可以提供可重复的结果,但这并不代表基础骨骼的运动。对于3D膝关节运动学的报告,提出了标准的测量误差。