首页> 外文期刊>Gait & posture >Effect of fatigue and hypohydration on gait characteristics during treadmill exercise in the heat while wearing firefighter thermal protective clothing.
【24h】

Effect of fatigue and hypohydration on gait characteristics during treadmill exercise in the heat while wearing firefighter thermal protective clothing.

机译:穿着消防员防热服的热度条件下,跑步机在炎热的运动中,疲劳和体液过少对步态特征的影响。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study compared the gait characteristics of individuals walking in heat while wearing firefighting equipment in fatigued and non-fatigued states. Nineteen subjects performed a 50-min treadmill protocol in a heated room while gait patterns were recorded using a digital video camcorder. Forty gait cycles were analyzed near the beginning (9 min) and at the end (39-49 min) of exercise. Spatio-temporal gait variables including step frequency, step length, swing time, stance time, cycle time and double-support time were determined. Gait variability was quantified by the standard deviation (SD) and coefficient of variation (CV) of each variable. Left-right symmetry was calculated using the symmetry index (SI) and symmetry angle (SA). Paired t-tests (alpha = 0.05) were performed to identify difference between the beginning and the end of the protocol for each measured variable. Spatio-temporal gait characteristics did not differ between the beginning and the end of exercise. Gait variability of the double-support time increased at the end as measured by both SD (P = 0.037) and CV (P = 0.030) but no change was observed for other variables. Left-right symmetry measured using either SI or SA did not differ between sessions. In summary, spatio-temporal gait characteristics and symmetry while wearing firefighting equipment are insensitive to physiological fatigue. Prolonged walking in heat while wearing firefighting equipment may increase gait variability and therefore the likelihood of a fall. Future studies are needed to confirm the potential relationship between fatigue and gait variability and to investigate the possible influence of individual variation.
机译:这项研究比较了在疲劳和非疲劳状态下穿着消防设备在热中行走的人的步态特征。 19名受试者在加热室内执行了50分钟的跑步机实验,同时使用数字视频便携式摄像机记录了步态模式。在运动开始时(9分钟)和运动结束时(39-49分钟)分析了40个步态周期。确定了时空步态变量,包括步频,步长,挥杆时间,站立时间,循环时间和双支撑时间。步态变异性通过每个变量的标准偏差(SD)和变异系数(CV)进行量化。使用对称指数(SI)和对称角度(SA)计算左右对称。进行配对的t检验(alpha = 0.05),以识别每个测量变量的方案开始和结束之间的差异。运动开始和结束之间的时空步态特征没有差异。通过SD(P = 0.037)和CV(P = 0.030)测得,双支撑时间的步态变异性最终增加。两次会议之间使用SI或SA测量的左右对称性没有差异。总之,穿着消防装备时的时空步态特征和对称性对生理疲劳不敏感。穿着消防设备长时间在火中行走可能会增加步态的变异性,并因此导致跌倒的可能性。需要进行进一步的研究,以确认疲劳与步态变异之间的潜在关系,并研究个体变异的可能影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有