Accuracy, sensitivity and robustness of five different methods for the estimation of gait temporal parameters using a single inertial sensor mounted on the lower trunk

机译:使用安装在下部行李箱上的单个惯性传感器估算五种不同方法来评估步态时间参数的准确性,灵敏度和鲁棒性

获取原文
获取原文并翻译 | 示例
           

摘要

In the last decade, various methods for the estimation of gait events and temporal parameters from the acceleration signals of a single inertial measurement unit (IMU) mounted at waist level have been proposed. Despite the growing interest for such methodologies, a thorough comparative analysis of methods with regards to number of extra and missed events, accuracy and robustness to IMU location is still missing in the literature. The aim of this work was to fill this gap. Five methods have been tested on single IMU data acquired from fourteen healthy subjects walking while being recorded by a stereo-photogrammetric system and two force platforms. The sensitivity in detecting initial and final contacts varied between 81% and 100% across methods, whereas the positive predictive values ranged between 94% and 100%. For all tested methods, stride and step time estimates were obtained; three of the selected methods also allowed estimation of stance, swing and double support time. Results showed that the accuracy in estimating step and stride durations was acceptable for all methods. Conversely, a statistical difference was found in the error in estimating stance, swing and double support time, due to the larger errors in the final contact determination. Except for one method, the IMU positioning on the lower trunk did not represent a critical factor for the estimation of gait temporal parameters. Results obtained in this study may not be applicable to pathologic gait.
机译:在过去的十年中,已经提出了各种用于从安装在腰部水平的单个惯性测量单元(IMU)的加速度信号估计步态事件和时间参数的方法。尽管人们对这种方法越来越感兴趣,但是在文献中仍然缺少关于额外事件和遗漏事件的数量,IMU定位的准确性和鲁棒性的方法的全面比较分析。这项工作的目的是填补这一空白。在从14个健康受试者的步行获得的单个IMU数据上,已经通过立体摄影测量系统和两个测力平台记录了五种方法的测试。在所有方法中,检测初始和最终接触的灵敏度在81%和100%之间变化,而阳性预测值在94%和100%之间变化。对于所有测试方法,都获得了步幅和步长时间估算值;所选的三种方法还可以估计姿势,挥杆和双支撑时间。结果表明,估算步长和步幅持续时间的准确性对于所有方法都是可以接受的。相反,由于最终接触确定中的较大误差,在估计姿态,挥杆和双支撑时间方面的误差中发现了统计差异。除了一种方法,IMU放在下躯干上并不代表估计步态时间参数的关键因素。在这项研究中获得的结果可能不适用于病理性步态。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号