首页> 外文期刊>Gait & posture >Validation of a pouch-mounted activPAL3 accelerometer
【24h】

Validation of a pouch-mounted activPAL3 accelerometer

机译:袋装activPAL3加速度计的验证

获取原文
获取原文并翻译 | 示例
           

摘要

The activPAL accelerometer is a commonly used device for the assessment of physical activity in cross-sectional and intervention research. These devices are usually attached directly to the skin; however, recent studies report problems such as skin irritation associated with this attachment method and therefore adequate alternate methods are needed. The aim of this study was to validate the use of an elasticised pouch to secure an activPAL3c (PAL Technologies, Glasgow, UK) accelerometer for the assessment of sedentary and physical activity behaviours during laboratory and free-living conditions. Twenty-eight healthy adults wore two activPAL3c accelerometers, one secured in an elasticised pouch, and one directly attached to the skin, on the anterior surface of the right thigh during laboratory-based walking at a self-selected pace, treadmill walking at 0.89 m s"1,1.56 m s^1 and running at 2.2 m s~ and during free-living conditions. Paired samples t-tests and intraclass correlation coefficients were used to investigate the difference and agreement between accelerometer outputs. No statistically significant difference in step count between pouch-mounted and skin-mounted activPAL3c accelerometers was evident during walking at any speed under laboratory conditions. No statistically significant difference in step count, upright time, sitting time or postural transitions was found between pouch-mounted and skin-mounted activPAL3c accelerometers during free-living conditions. Intraclass correlation coefficients showed a high to very high level of agreement between pouch-mounted and skin-mounted activPAL3c accelerometers for each outcome variable. The use of an elasticised pouch to secure the activPAL3c accelerometer appears to be a valid method of attachment and may offer advantages over direct skin mounting.
机译:activPAL加速度计是在横断面和干预研究中评估身体活动的常用设备。这些设备通常直接附着在皮肤上。但是,最近的研究报告了这种附着方法相关的皮肤刺激等问题,因此需要适当的替代方法。这项研究的目的是验证使用弹性袋固定activPAL3c(PAL Technologies,英国格拉斯哥)加速度计,以评估实验室和自由生活条件下久坐和身体活动的行为。 28名健康成人在以自主选择的速度进行基于实验室的行走,在跑步机上行走0.89 ms的过程中,在右大腿上佩戴了两个activPAL3c加速度计,一个固定在松紧的小袋中,一个直接固定在皮肤上。 “ 1,1.56 ms ^ 1,以2.2 ms〜的速度运行,并且处于自由活动状态。使用成对样本t检验和类内相关系数研究加速度计输出之间的差异和一致性。步骤之间的统计差异无统计学意义在实验室条件下以任何速度行走时,袋装式和皮装式ActivPAL3c加速度计均很明显,袋装式和皮装式ActivPAL3c加速度计在自由运动期间的步数,直立时间,就坐时间或姿势转变均无统计学意义差异。生活条件:类内相关系数表明,袋装式和小袋装之间的一致性高到非常高每个结果变量的近亲型activPAL3c加速度计。使用弹性袋固定activPAL3c加速度计似乎是一种有效的连接方法,并且可能比直接安装皮肤更具优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号