首页> 外文期刊>Gait & posture >Quantification and reliability of center of pressure movement during balance tasks of varying difficulty
【24h】

Quantification and reliability of center of pressure movement during balance tasks of varying difficulty

机译:不同难度的平衡任务中压力运动中心的量化和可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

Postural control is often assessed by quantifying the magnitude of the center of pressure (COP) movement. However, these measures usually focus on the gross amount of movement and ignore the temporal structure of the COP signal. A novel non-linear analysis technique was recently developed to characterize the temporal structure of the COP signal with an output termed the entropic half-life [E(1/2)]. The E(1/2) reflects how much of the previous postural position is used to determine the current postural control strategy (memory effect). The purpose of this study was to quantify the E(1/2) and four COP movement magnitude measurements (medio-lateral and anterior-posterior excursion, path length, 95% ellipse area) for balance tasks increasing in sensory difficulty, as well as the test-retest reliability of each measure. Twenty-seven healthy young adults completed single limb stance tasks varying in sensory difficulty (rigid surface eyes open, rigid surface eyes closed, foam surface eyes open) on two separate occasions. Relative reliability was assessed using an intraclass correlation coefficient (ICC3,3). Absolute reliability was assessed using the standard error of the measurement (SEM) and the sensitivity of the measurement to true changes was assessed using the minimal detectable change (MDC95). The E(1/2) was found to have excellent reliability for all tasks tested (ICC range 0.82-0.91, SEM range 3.5-14.1mm, MCD95 range 9.7-39.2mm). The high reliability of the E(1/2) was comparable to that of movement magnitude measurements. This may be used in order to better understand the underlying motor control system.
机译:通常通过量化压力中心(COP)运动的幅度来评估姿势控制。但是,这些措施通常集中在总运动量上,而忽略了COP信号的时间结构。最近开发了一种新颖的非线性分析技术来表征COP信号的时间结构,并带有称为熵半衰期[E(1/2)]的输出。 E(1/2)反映了以前的姿势位置中的多少用于确定当前的姿势控制策略(记忆效应)。这项研究的目的是量化E(1/2)和四个COP运动幅度的测量值(中外侧和前后偏移,路径长度,95%的椭圆面积),以平衡感官难度增加以及每个度量的重测可靠性。二十七名健康的年轻成年人分别在两次不同的情况下完成了单肢姿势任务,这些任务的感觉难度​​各不相同(硬面眼睛张开,硬面眼睛闭合,泡沫面眼睛睁开)。使用组内相关系数(ICC3,3)评估相对可靠性。使用测量的标准误差(SEM)评估绝对可靠性,并使用最小的可检测变化(MDC95)评估测量对真实变化的敏感性。发现E(1/2)对所有测试任务具有出色的可靠性(ICC范围为0.82-0.91,SEM范围为3.5-14.1mm,MCD95范围为9.7-39.2mm)。 E(1/2)的高可靠性可与运动幅度测量相媲美。可以使用它来更好地理解基础的电机控制系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号