首页> 外文期刊>Gait & posture >Reliability of principal components and discrete parameters of knee angle and moment gait waveforms in individuals with moderate knee osteoarthritis
【24h】

Reliability of principal components and discrete parameters of knee angle and moment gait waveforms in individuals with moderate knee osteoarthritis

机译:膝关节中度骨关节炎患者主成分的可靠性和膝关节角和力矩步态波形的离散参数

获取原文
获取原文并翻译 | 示例
           

摘要

Gait measures are used to evaluate change in patients with knee osteoarthritis (OA), but reliability has not been fully established in this population. This study examined test-retest reliability of knee angle and moment gait waveform characteristics captured using discrete parameters and principal component analysis (PCA) in individuals with moderate knee OA. Participants (n=20) underwent three-dimensional gait analysis on two occasions. Motion and force data were captured using two camera banks, infrared light emitting diodes and force plate during self-selected walking. Knee angle and moment waveforms were calculated and analyzed using discrete parameters and by identifying waveform characteristics using PCA. Intraclass correlation coefficients (ICC2,k) examined test-retest reliability of discrete parameters and PCA derived scores (PC-scores). ICC2,k values ranged from 0.57 to 0.93 for discrete parameters, 0.52-0.86 for knee angle PC-scores and 0.30-0.94 for the knee moment PC-scores. However, 10 of 13 discrete parameters, six of nine knee angle PC-scores and seven of nine knee moment PC-scores had ICC2,k values greater than or equal to 0.70. Discrete parameters and PC-scores from flexion angles and adduction moments had the highest ICC2,k values while adduction angles, rotation angles, and rotation moments had the lowest. Most knee angle and moment waveform characteristics demonstrated ICC2,k values that could be interpreted as acceptable. Caution should be used when examining adduction and rotation angle magnitudes and early/mid-stance rotation moment magnitudes due to lower ICC2,k values.
机译:步态测量方法用于评估膝骨关节炎(OA)患者的变化,但该人群的可靠性尚未完全确立。这项研究检查了中度膝关节OA患者使用离散参数和主成分分析(PCA)捕获的膝关节角和步态波形特征的重测可靠性。参与者(n = 20)进行了两次三维步态分析。在自选行走过程中,使用两个摄像头组,红外发光二极管和测力板捕获运动和力数据。使用离散参数并通过使用PCA识别波形特征来计算和分析膝盖角度和力矩波形。类内相关系数(ICC2,k)检查离散参数的重测信度和PCA得出的分数(PC评分)。对于离散参数,ICC2,k值的范围从0.57到0.93,对于膝角PC得分的ICC2,k值在0.52-0.86之间,对于膝弯矩PC得分的ICC2,k值在0.30-0.94之间。但是,13个离散参数中的10个,9个膝角PC分数中的6个和9个膝力矩PC分数中的7个具有ICC2,k值大于或等于0.70。屈曲角和内收力矩的离散参数和PC分数具有最高的ICC2,k值,而内收角,旋转角和旋转力矩的ICC2,k值最低。大多数膝关节角度和力矩波形特性显示出ICC2,k值,可以解释为可接受。由于较低的ICC2,k值,在检查内收角和旋转角幅度以及早期/中级旋转力矩幅度时应谨慎。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号