首页> 外文期刊>Gait & posture >Reliability of head and trunk kinematics during gait in children with spastic diplegia
【24h】

Reliability of head and trunk kinematics during gait in children with spastic diplegia

机译:痉挛性截瘫儿童步态时头部和躯干运动学的可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

This study describes the reliability of a clinically oriented model for three-dimensional movement analysis of head and trunk movements in children with spastic diplegia. The model consists of five rigid segments (head, thorax, pelvis, shoulder line, spine) and includes a detailed analysis of spinal segmental movements. Within and between session reliability during gait was tested in 10 children with spastic diplegia (6-14. yrs). Reliability of discrete parameters was assessed with the intraclass correlation coefficient (ICC) and similarity of thorax and pelvis waveforms with the coefficient of multiple correlation (CMC). Measurement errors were calculated for all parameters (SEM, ??). Results indicated acceptable within and between session reliability of discrete parameters for thorax, pelvis, shoulder line, angle of kyphosis and the majority of the spinal segmental angles, reflected by low SEMs (<4??) and most ICCs. >0.60. Within and between session waveform errors were below 4??. CMCs ranged from poor to very good, with highest values for movements in the frontal and transversal planes. The angle of lordosis showed lower between session reliability for several discrete parameters, although waveform errors were still below 5??. Head parameters showed lower overall reliability. The results of this study support the reliability of the proposed model. Head kinematic parameters should be interpreted with caution, due to difficulties in standardization. Accurate palpation of the spinal markers, especially the lumbar spine, is critical and demands thorough training of the assessor. ? 2012 Elsevier B.V.
机译:这项研究描述了针对痉挛性截瘫儿童头部和躯干运动的三维运动分析的临床模型的可靠性。该模型包括五个刚性部分(头部,胸部,骨盆,肩线,脊柱),并包括对脊柱节段运动的详细分析。在10名患有痉挛性截瘫(6-14岁)的儿童中测试了步态内和步态之间的可靠性。使用组内相关系数(ICC)评估离散参数的可靠性,并使用多重相关系数(CMC)评估胸廓和骨盆波形的相似性。计算所有参数(SEM,Δε)的测量误差。结果表明,在较低的SEM(<4?)和大多数ICC反映的胸,骨盆,肩线,驼背角和大部分脊柱节段角离散参数的会话可靠性内和会话可靠性之间是可接受的。 > 0.60。会话期间内和之间的波形误差均低于4。 CMC的范围从差到非常好,在额平面和横向平面的移动值最高。尽管波形误差仍低于5Ω,但脊柱前凸角度在几个离散参数的会话可靠性之间较低。磁头参数显示出较低的整体可靠性。这项研究的结果支持了所提出模型的可靠性。由于标准化困难,应谨慎解释头部运动学参数。正确触诊脊柱标志物,尤其是腰椎,至关重要,需要对评估者进行彻底的培训。 ? 2012年Elsevier B.V.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号