Objective: The general consensus to date has been that a stimulus repetition rate of 40. Hz is not appropriate for the recording of auditory steady-state responses (ASSR) in sedated or anaesthetized infants. The aim of this study was to investigate whether reliable 40-Hz ASSR thresholds can be obtained in sedated infants using narrow-band chirp stimuli in the clinical routine. Methods: 40-Hz auditory brainstem responses (ABR) and 40-Hz ASSR were recorded in 34 infants below the age of 48 months under sedation or under general anaesthesia. ABR were evoked by broad-band chirp stimuli with a flat amplitude spectrum. ASSR were recorded simultaneously from both ears with an adaptive multiple stimulus paradigm using four narrow-band chirps centred at 500, 1000, 2000 and 4000. Hz. ABR and ASSR thresholds were evaluated to determine differences between the estimates from the two methods. Results: Despite of sedation and anaesthesia, large wave V amplitudes of the chirp evoked 40-Hz ABR were found at levels as low as 10. dB above the individual ABR threshold. ASSR thresholds for stimulus repetition rates of 40. Hz could be consistently estimated in all 34 infants. Thresholds estimated from the ASSR for the four frequencies of the narrow-band chirps and the threshold derived from the broad-band chirp ABR differ, on average by 3.7. dB for the frequency range of 1000-2000. Hz and 7.1. dB for the frequency range from 2000 to 4000. Hz. Conclusion: In contrast to the general assumption that 40-Hz ASSR are not appropriate for threshold estimation in infants our results demonstrate that multiple ASSR with a stimulus repetition rate of 40. Hz can be recorded in sedated and anaesthetized infants using narrow-band chirps. Threshold estimates obtained with 40-Hz ASSR are, on average, slightly higher than those obtained with chirp evoked ABR but allow for a frequency specific characterisation of the hearing ability.
机译:目的:迄今为止,普遍共识是刺激重复频率为40 Hz不适合记录镇静或麻醉婴儿的听觉稳态反应(ASSR)。这项研究的目的是研究在临床常规中使用窄带chi声刺激可以在镇静的婴儿中获得可靠的40 Hz ASSR阈值。方法:在34例48个月以下的镇静或全身麻醉下记录40 Hz听觉脑干反应(ABR)和40 Hz ASSR。 ABR是由具有平坦振幅谱的宽带rp刺激引起的。使用四个以500、1000、2000和4000 Hz为中心的窄带chi,通过自适应多重刺激范例从两只耳朵同时记录了ASSR。评估了ABR和ASSR阈值,以确定两种方法的估计值之间的差异。结果:尽管有镇静和麻醉作用,found声诱发的40 Hz ABR的大波V幅值仍比单个ABR阈值低10 dB。可以在所有34例婴儿中一致地估计出刺激重复率40. Hz的ASSR阈值。从ASSR估计的窄带线性调频信号的四个频率的阈值与宽带宽带线性调频信号的ABR得出的阈值平均相差3.7。在1000-2000的频率范围内为dB。 Hz和7.1。从2000到4000。Hz的dB。结论:与40 Hz ASSR不适合婴儿阈值估计的一般假设相反,我们的结果表明,使用窄带chi可以在镇静和麻醉的婴儿中记录多个重复频率为40 Hz的ASSR。平均而言,使用40 Hz ASSR获得的阈值估计值略高于使用chi诱发的ABR获得的阈值估计值,但可以对听觉能力进行特定频率的表征。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号