High-performance polymer microlens arrays were fabricated by means of withdrawing substrates of patterned wettability from a monomer solution. The f-number (f~(#)) of formed microlenses was controlled by adjustment of monomer viscosity and surface tension, substrate dipping angle and withdrawal speed, the array fill factor, and the number of dip coats used. An optimum withdrawal speed was identified at which f~(#) was minimized and array uniformity was maximized. At this optimum, arrays of f/3.48 microlenses were fabricated with one dip coat with uniformity of better than Δf/f~±3.8%. Multiple dip coats allowed for production of f/1.38 lens arrays and uniformity of better than Δf/f~±5.9%. Average f~(#)s were reproducible to within 3.5%. A model was developed to describe the fluid-transfer process by which monomer solution assembles on the hydrophilic domains. The model agrees well with experimental trends.
机译:高性能聚合物微透镜阵列是通过从单体溶液中抽出具有图案化润湿性的基板来制造的。通过调节单体粘度和表面张力,基材浸入角和撤出速度,阵列填充系数和浸涂次数,可以控制所形成的微透镜的f值(f〜(#))。确定了最佳的退出速度,在该速度下f〜(#)最小且阵列均匀性最大。在此最佳条件下,用一层浸涂法制备的f / 3.48微透镜阵列的均匀性优于Δf/ f〜±3.8%。多次浸涂可以生产f / 1.38透镜阵列,均匀度优于Δf/ f〜±5.9%。平均f〜(#)s可再现到3.5%以内。开发了一个模型来描述单体溶液在亲水域上组装的流体传输过程。该模型与实验趋势非常吻合。