首页> 外文期刊>Applied optics >Use of low-coherence speckled speckles for bioflow measurements
【24h】

Use of low-coherence speckled speckles for bioflow measurements

机译:使用低相干斑点斑点进行生物流量测量

获取原文
获取原文并翻译 | 示例
           

摘要

Formation of speckled speckles in the case of biflow perfusion by partially coherent light was considered. Dependencies of statistical characteristics of low-coherence biospeckles with a small number of scatterers on the scattering properties of the flow and on the coherence length of incident light were analyzed. It was shown that the value of the Doppler bandwidth in the scattered light essentially depends on the ratio between the coherence length and the average size of the flow's inhomogeneities. A procedure for reconstructing velocity distribution in a single blood vessel was suggested.
机译:考虑在通过部分相干光进行双流灌注的情况下形成斑点斑点。分析了具有少量散射体的低相干生物散斑的统计特性对流的散射特性和入射光的相干长度的依赖性。结果表明,散射光中多普勒带宽的值基本上取决于相干长度与流动不均匀性的平均大小之间的比率。建议了在单个血管中重建速度分布的程序。