We experimentally investigate the influence of O-2 interferences on laser-induced fluorescence measurements of NO in lean methane-fueled flames at a range of pressures for both narrow-band and broadband fluorescence detection. We identify NO excitation schemes that minimize O-2 interferences. From detection scans we obtain interference spectra for the different NO excitation schemes. We then identify optimum excitation-detection schemes for narrow-band detection measurements of NO. To simulate broadband detection experiments, we numerically apply five different filter combinations to the experimentally obtained detection scans. We develop filter-assessment parameters to judge the effectiveness of the different filtering schemes, and we establish a methodology for evaluating broadband excitation-detection strategies. From this research we identify optimum excitation-detection schemes for broadband detection measurements of NO. (C) 1996 Optical Society of America [References: 28]
机译:我们实验研究O-2干扰对窄带和宽带荧光检测在一定压力范围内的贫甲烷燃烧火焰中NO的激光诱导的NO的荧光测量的影响。我们确定了NO激励方案,可以最大程度地减少O-2干扰。从检测扫描中,我们获得了不同NO激发方案的干扰光谱。然后,我们确定用于NO的窄带检测测量的最佳激励检测方案。为了模拟宽带检测实验,我们在数值上将五个不同的滤镜组合应用于实验获得的检测扫描。我们开发了滤波器评估参数来判断不同滤波方案的有效性,并建立了一种评估宽带激励检测策略的方法。从这项研究中,我们确定了用于NO的宽带检测测量的最佳激励检测方案。 (C)1996年美国眼镜学会[参考文献:28]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号