首页> 外文期刊>Applied optics >Measurement of localized heating in the focus of an optical trap
【24h】

Measurement of localized heating in the focus of an optical trap

机译:测量光阱焦点内的局部加热

获取原文
获取原文并翻译 | 示例
           

摘要

Localized heating in the focus of an optical trap operating in water can result in a temperature rise of several kelvins. We present spatially resolved measurements of the refractive-index distribution induced by the localized heating produced in an optical trap and infer the temperature distribution. We have determined a peak temperature rise in water of 4 K in the focus of a 985-nm-wavelength 55-mW laser beam. The localized heating is directly proportional to power and the absorption coefficient. The temperature distribution is in excellent agreement with a model based on the heat equation.
机译:在水中工作的光阱的焦点处的局部加热会导致温度升高几个开尔文。我们介绍了由光学陷阱中产生的局部加热引起的折射率分布的空间分辨测量结果,并推断出温度分布。我们在985 nm波长的55 mW激光束的焦点处确定了4 K的水中的峰值温度升高。局部加热与功率和吸收系数成正比。温度分布与基于热方程的模型非常吻合。