首页> 外文期刊>BioMed research international >Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate
【24h】

Clinical Effects of the Probing Method with Depth Gauge for Determining the Screw Depth of Locking Proximal Humeral Plate

机译:探测方法用深度计确定锁定近端肱骨板螺杆深度的临床影响

获取原文
获取原文并翻译 | 示例
           

摘要

Background. The use of locking plates has gained popularity to treat proximal humeral fractures. However, the complication rates remain high. Biomechanical study suggested that subchondral screw-tip abutment significantly increased the stability of plant. We present a simple method to obtain the proper screw length through the depth gauge in elderly patients and compared the clinical effects with traditional measuring method. Methods. 40 patients were separated into two groups according to the two surgical methods: the probing method with depth gauge and the traditional measuring method. The intraoperative indexes and postoperative complications were recorded. The Constant and Murley score was used for the functional assessment in the 12th month. Results. Operative time and intraoperative blood loss indicated no statistical differences. X-ray exposure time and the patients with screw path penetrating the articular cartilage significantly differed. Postoperative complications and Constant and Murley score showed no statistical differences. Conclusions. Probing method with depth gauge is an appropriate alternative to determine the screw length, which can make the screw-tip adjoin the subchondral bone and keep the articular surface of humeral head intact and at the same time effectively avoid frequent X-ray fluoroscopy and adjusting the screws.
机译:背景。锁定板的使用已经获得了处理近端肱骨骨折的普及。但是,并发症率仍然很高。生物力学研究表明,子螺旋尖端桥面显着提高了植物的稳定性。我们提出了一种简单的方法,可以通过老年患者的深度计获得适当的螺钉长度,并将临床效应与传统的测量方法进行了比较。方法。根据两个手术方法将40名患者分成两组:深度计的探测方法和传统的测量方法。记录了术中指标和术后并发症。常数和Murley评分用于12个月的功能评估。结果。手术时间和术中失血表明没有统计差异。 X射线暴露时间和螺旋道患者穿透关节软骨显着差异。术后并发症和常数和Murley评分没有统计差异。结论。具有深度计的探测方法是确定螺杆长度的适当替代方案,可以使螺纹尖端邻近骨折骨骼并保持肱骨头的关节表面完整,同时有效地避免频繁X射线透视和调节频繁X射线透视和调节螺丝。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号