Objective-To compare the diagnostic quality of bronchoalveolar lavage (BAL) fluid acquired from healthy dogs by manual aspiration via polyethylene tubing (MAPT) and via suction pump aspiration (SPA) with a suction trap connection. Animals-12 healthy adult Beagles. Procedures-BAL was performed with bronchoscopic guidance in anesthetized dogs. The MAPT was performed with a 35-mL syringe attached to polyethylene tubing wedged in a bronchus via the bronchoscope's biopsy channel. The SPA was performed with 5 kPa of negative pressure applied to the bronchoscope's suction valve via a suction trap. The MAPT and SPA techniques were performed in randomized order on opposite caudal lung lobes of each dog. Two 1 mL/kg lavages were performed per site. Samples of BAL fluid were analyzed on the basis of a semiquantitative quality scale, percentage of retrieved fluid, and total nucleated and differential cell counts. Results were compared with Wilcoxon signed rank tests. Results-Percentage of BAL fluid retrieved (median difference, 16.2%), surfactant score (median difference, 1), and neutrophil count (median difference, 74 cells/pt) were significantly higher for SPA than for MAPT. A higher BAL fluid epithelial cell score was obtained via MAPT, compared with that for samples obtained via SPA (median difference, 1). Conclusions and Clinical Relevance-Results indicated that in healthy dogs, SPA provided a higher percentage of BAL fluid retrieval than did MAPT. The SPA technique may improve the rate of diagnostic success for BAL in dogs, compared with that for MAPT. Further evaluation of these aspiration techniques in dogs with respiratory tract disease is required. (Am J Vet Res 2013;74:523-529)
机译:目的-比较通过聚乙烯管(MAPT)手动抽吸和通过带抽吸阱连接的抽吸泵抽吸(SPA)从健康犬身上采集的支气管肺泡灌洗液(BAL)的诊断质量。动物12个健康的成年小猎犬。在麻醉的狗中,在支气管镜引导下进行程序-BAL。使用通过支气管镜活检通道楔入在支气管中的聚乙烯管的35 mL注射器执行MAPT。 SPA是在通过吸水管施加到支气管镜的吸气阀的5 kPa负压下执行的。 MAPT和SPA技术以随机顺序在每只狗的相反尾肺叶上进行。每个部位进行两次1 mL / kg灌洗。根据半定量质量标度,回收的液体百分比以及总有核和差异细胞计数,对BAL液体样品进行了分析。将结果与Wilcoxon签名秩检验进行比较。结果:SPA的取回BAL液的百分比(中位数差异,为16.2%),表面活性剂得分(中位数差异,为1)和中性粒细胞计数(中位数差异为74个细胞/点)显着高于MAPT。与通过SPA获得的样品相比,通过MAPT获得的BAL液上皮细胞得分更高(中位数差为1)。结论和临床相关性结果表明,在健康犬中,SPA提供的BAL液回收率高于MAPT。与MAPT相比,SPA技术可以提高狗中BAL的诊断成功率。需要对患有呼吸道疾病的犬的这些抽吸技术进行进一步评估。 (Am J Vet Res 2013; 74:523-529)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号