首页> 外文期刊>Biotechnology Progress >Effects of Chemical Sanitization Using NaOH on the Properties of Polysulfone and Polyethersulfone Ultrafiltration Membranes
【24h】

Effects of Chemical Sanitization Using NaOH on the Properties of Polysulfone and Polyethersulfone Ultrafiltration Membranes

机译:NaOH化学消毒对聚砜和聚醚砜超滤膜性能的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Membranes used in bioprocessing applications are typically sanitized before use to insure aseptic operation. However, there is almost no information in the literature on the effects of this preuse sanitization step on the properties of the membrane. Experiments were performed with commercially available hollow fiber polysulfone (PSf) and polyethersulfone (PES) membranes with different nominal molecular weight cutoffs. Data were obtained for the membrane hydraulic permeability, dextran retention coefficients, zeta potential (surface charge), and extent of protein adsorption both before and after sanitization with 0.5 N NaOH at 45 degrees C for 30 min. Changes in chemical composition were examined using ATR-FT-IR and XPS. Sanitization caused a large increase in the net negative charge for all membranes. There was a small reduction in hydraulic permeability and a significant increase in dextran retention for the polyethersulfone membranes, consistent with a reduction in the effective pore size. Spectroscopic analyses suggest that this change is likely due to the base-catalyzed hydrolysis of the lactam ring in polyvinylpyrrolidone (PVP) that is typically is used as a wetting/pore-forming agent in PSf and PES membranes. Preuse sanitization also appeared to have a small effect on protein adsorption, although the extent of adsorption was quite low for both the virgin and sanitized membranes. The observed changes in membrane properties could have a significant impact on the ultrafiltration performance, demonstrating the importance of standardizing the sanitization procedures even in process development and scale-down validation studies. (c) 2014 American Institute of Chemical Engineers Biotechnol. Prog., 31:90-96, 2015
机译:生物处理应用中使用的膜通常在使用前经过消毒,以确保无菌操作。然而,在文献中几乎没有关于该使用前消毒步骤对膜性能的影响的信息。用市售的中空纤维聚砜(PSf)和聚醚砜(PES)膜进行了标称截留值不同的实验。获得了在45°C下用0.5 N NaOH消毒30分钟之前和之后的膜水力渗透率,右旋糖酐保留系数,ζ电位(表面电荷)和蛋白质吸附程度的数据。使用ATR-FT-IR和XPS检查化学成分的变化。消毒导致所有膜的净负电荷大大增加。聚醚砜膜的水力渗透性略有下降,右旋糖酐的保留量显着增加,这与有效孔径的减小相一致。光谱分析表明,这种变化可能是由于聚乙烯吡咯烷酮(PVP)中内酰胺环的碱催化水解,该聚乙烯吡咯烷酮通常用作PSf和PES膜的润湿/成孔剂。尽管未用过的膜和经过消毒的膜的吸附程度都非常低,但使用前的消毒处理似乎对蛋白质的吸附影响很小。观察到的膜性能变化可能会对超滤性能产生重大影响,这表明即使在工艺开发和按比例缩小的验证研究中,标准化消毒程序的重要性也是如此。 (c)2014美国化学工程师学会生物技术学会。 Prog。,31:90-96,2015

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号