首页> 外文期刊>Journal of magnetic resonance imaging: JMRI >Phase contrast MRI measurements of net cerebrospinal fluid flow through the cerebral aqueduct are confounded by respiration
【24h】

Phase contrast MRI measurements of net cerebrospinal fluid flow through the cerebral aqueduct are confounded by respiration

机译:通过脑渡管通过呼吸呼吸的相腺液体流动的相对比MRI测量

获取原文
获取原文并翻译 | 示例
           

摘要

Background Net cerebrospinal fluid (CSF) flow through the cerebral aqueduct may serve as a marker of CSF production in the lateral ventricles, and changes that occur with aging and in disease. Purpose To investigate the confounding influence of the respiratory cycle on net CSF flow and stroke volume measurements. Study Type Cross-sectional study. Subjects Twelve young, healthy subjects (seven male, age range 19-39 years, average age 28.3 years). Field Strength/Sequence Phase contrast MRI (PC-MRI) measurements were performed at 7T, with and without respiratory gating on expiration and on inspiration. All measurements were repeated. Assessment Net CSF flow and stroke volume in the aqueduct, over the cardiac cycle, was determined. Statistical Tests Repeatability was determined using the intraclass correlation coefficient (ICC) and linear regression analysis between the repeated measurements. Repeated measures analysis of variance (ANOVA) was performed to compare the measurements during inspiration/expiration/no gating. Linear regression analysis was performed between the net CSF flow difference (inspiration minus expiration) and stroke volume. Results Net CSF flow (average +/- standard deviation) was 0.64 +/- 0.32 mL/min (caudal) during expiration, 0.12 +/- 0.49 mL/min (cranial) during inspiration, and 0.31 +/- 0.18 mL/min (caudal) without respiratory gating. Respiratory gating did not affect stroke volume measurements (41 +/- 18, 42 +/- 19, 42 +/- 19 mu L/cycle for expiration, no respiratory gating and inspiration, respectively). Repeatability was best during inspiration (ICC = 0.88/0.56/-0.31 for gating on inspiration/expiration/no gating). A positive association was found between average stroke volume and net flow difference between inspiration and expiration (R = 0.678/0.605, P = 0.015/0.037 for the first/second repeated measurement). Data Conclusion Measured net CSF flow is confounded by respiration effects. Therefore, net CSF flow measurements with PC-MRI cannot in isolation be directly linked to CSF production. Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:433-444.
机译:背景技术净脑液(CSF)流过脑渡源库的流动可以用作侧脑室中CSF产生的标记,以及随老化和疾病发生的变化。目的探讨呼吸周期对净CSF流量和行程体积测量的混淆影响。研究类型横截面研究。受试者十二名年轻,健康科目(七名男性,年龄范围19-39岁,平均年龄28.3岁)。场强/序列相位对比MRI(PC-MRI)测量在7T中进行,随着呼吸和吸气的呼吸门和吸气。重复所有测量。确定了在心脏周期中的评估净CSF流程和中风体积。统计测试使用脑内相关系数(ICC)和重复测量之间的线性回归分析确定统计测试可重复性。重复措施的差异分析(ANOVA)进行进行,以比较灵感/到期/无门控的测量。在净CSF流动差(启发减去呼气)和行程体积之间进行线性回归分析。结果净CSF流(平均+/-标准偏差)在呼气期间为0.64 +/- 0.32 mL / min(尾部),灵感期间0.12 +/- 0.49 ml / min(颅骨),0.31 +/- 0.18 ml / min (尾部)没有呼吸门控。呼吸门不影响卒中体积测量(41 +/- 18,42 +/- 19,42 +/-19μl/循环分别用于呼吸,没有呼吸门控和灵感)。灵感期间,可重复性最佳(ICC = 0.88 / 0.56 / -0.31,用于鼓舞的灵感/到期/无门控)。在平均行程体积和灵感和到期之间的净流动差之间发现了阳性关联(R = 0.678 / 0.605,P = 0.015 / 0.037,用于第一/第二重复测量)。数据结论测量净CSF流量被呼吸效果混淆。因此,使用PC-MRI的NET CSF流量测量不能被隔离直接与CSF生产相关联。技术疗效:第2阶段J. MANG。恢复。 2019年成像; 49:433-444。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号