OBJECTIVE: The objective of our study was to determine whether the use of a computer-aided diagnosis (CAD) system can shorten the reading time while maintaining the diagnostic performance of MR angiography for the detection of intracranial aneurysms. MATERIALS AND METHODS: Fifty maximum-intensity-projection MR angiograms in 50 patients (16 intracranial aneurysms and 34 negative cases) were used for this observer performance study. Sixteen radiologists--eight neuroradiologists and eight less experienced radiologists--participated in the observer studies and interpreted the MR angiograms without and with CAD output images using an independent test method. The reading times without and with CAD were compared separately for the aneurysm and negative cases. The observers' performances were evaluated using receiver operating characteristic (ROC) analysis. We analyzed separately the data obtained from neuroradiologists and from less experienced radiologists. RESULTS: For all observers, the mean area under theROC curve (Az) with CAD was improved compared with that without CAD (0.903 vs 0.851, respectively; p = 0.109), and the mean reading time per case was reduced significantly by 18.1 seconds (28.5%) (from 63.4 to 45.3 seconds, p < 0.05). When CAD output images were available, the mean A(z) for the less experienced radiologists was significantly improved (0.911 vs 0.787, p < 0.05), but not for the neuroradiologists. The mean reading time of the less experienced radiologists with CAD was significantly shorter than that of the neuroradiologists without CAD (39.8 vs 54.5 seconds, p < 0.05). CONCLUSION: The use of a CAD system for the detection of intracranial aneurysms on MR angiography can shorten the reading time while improving diagnostic performance for less experienced radiologists.
机译:目的:我们的研究目的是确定使用计算机辅助诊断(CAD)系统是否可以缩短阅读时间,同时保持MR血管造影对颅内动脉瘤的诊断性能。材料与方法:本研究采用50例50例最大强度投影MR血管造影照片(16例颅内动脉瘤和34例阴性病例)进行观察。十六名放射科医生-八名神经放射科医生和八名经验不足的放射科医生-参加了观察者研究,并使用独立的测试方法解释了无或有CAD输出图像的MR血管造影。对于动脉瘤和阴性病例,分别比较不使用CAD和使用CAD的阅读时间。使用接收机工作特性(ROC)分析评估了观察员的表现。我们分别分析了从神经放射科医生和经验不足的放射科医生那里获得的数据。结果:对于所有观察者,与无CAD相比,有CAD的ROC曲线下平均面积(Az)有所改善(分别为0.903和0.851; p = 0.109),每例平均阅读时间显着减少了18.1秒( 28.5%)(从63.4到45.3秒,p <0.05)。当CAD输出图像可用时,经验不足的放射线医师的平均A(z)显着提高(0.911 vs 0.787,p <0.05),而神经放射线医师则没有。经验丰富的CAD放射线医师的平均阅读时间明显短于没有CAD的神经放射线医师(39.8 vs 54.5秒,p <0.05)。结论:使用CAD系统在MR血管造影上检测颅内动脉瘤可以缩短读取时间,同时改善对经验不足的放射科医生的诊断性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号