...
【24h】

Degeneration of the long biceps tendon: comparison of MRI with gross anatomy and histology.

机译:长二头肌腱变性:MRI与大体解剖学和组织学的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: The objective of our study was to relate alterations in biceps tendon diameter and signal on MR images to gross anatomy and histology. MATERIALS AND METHODS: T1-weighted, T2-weighted fat-saturated, and proton density-weighted fat-saturated spin-echo sequences were acquired in 15 cadaveric shoulders. Biceps tendon diameter (normal, flattened, thickened, and partially or completely torn) and signal intensity (compared with bone, fat, muscle, and joint fluid) were graded by two readers independently and in a blinded fashion. The distance of tendon abnormalities from the attachment at the glenoid were noted in millimeters. MRI findings were related to gross anatomic and histologic findings. RESULTS: On the basis of gross anatomy, there were six normal, five flattened, two thickened, and two partially torn tendons. Reader 1 graded nine diameter changes correctly, missed two, and incorrectly graded four. The corresponding values for reader 2 were seven, one, and five, respectively, with kappa = 0.75. Histology showed mucoid degeneration (n = 13), lipoid degeneration (n = 7), and fatty infiltration (n = 6). At least one type of abnormality was found in each single tendon. Mucoid degeneration was hyperintense compared with fatty infiltration on T2-weighted fat-saturated images and hyperintense compared with magic-angle artifacts on proton density-weighted fat-saturated images. MRI-based localization of degeneration agreed well with histologic findings. CONCLUSION: Diameter changes are specific but not sensitive in diagnosing tendinopathy of the biceps tendon. Increased tendon signal is most typical for mucoid degeneration but should be used with care as a sign of tendon degeneration.
机译:目的:我们的研究目的是将二头肌腱直径的改变和MR图像上的信号与大体解剖和组织学联系起来。材料与方法:在15个尸体肩膀上采集了T1加权,T2加权饱和脂肪和质子密度加权脂肪饱和自旋回波序列。二头肌的肌腱直径(正常,变平,变厚,部分或完全撕裂)和信号强度(与骨骼,脂肪,肌肉和关节液相比)由两名读者分别以盲法进行评分。距关节盂附着处的腱异常距离以毫米记录。 MRI检查结果与大体解剖和组织学检查结果相关。结果:根据大体解剖,有6条正常,5条扁平,2条增厚和2条部分撕裂的肌腱。读取器1正确地为九个直径变化评分,错过了两个,而错误地为四个评分。读取器2的相应值分别为7、1、5,kappa = 0.75。组织学显示粘液样变性(n = 13),脂质样变性(n = 7)和脂肪浸润(n = 6)。在每个单个肌腱中至少发现一种异常。与T2加权的脂肪饱和图像上的脂肪浸润相比,粘液样变性具有高强度,而与质子密度加权的脂肪饱和图像上的魔角伪影相比,具有高强度。基于MRI的变性定位与组织学检查结果非常吻合。结论:直径变化是特异性的,但对二头肌腱肌腱病变的诊断不敏感。肌腱变性最典型的是肌腱信号增加,但应谨慎使用,以示肌腱变性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号