【24h】

Pulmonary 64-MDCT angiography with 30 mL of IV contrast material: Vascular enhancement and image quality

机译:含30 mL IV造影剂的肺部64-MDCT血管造影:血管增强和图像质量

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE. The objective of our study was to determine whether vascular enhancement and image quality can be preserved in pulmonary CT angiography (CTA) performed on a 64-MDCT scanner with 30 mL of IV contrast material. MATERIALS AND METHODS. This retrospective matched-cohort study compared image quality of pulmonary CTA performed using 30 mL of IV contrast material versus 100 mL of IV contrast material. CT images of 50 patients (46 men, four women; mean age, 66 years) who underwent pulmonary CTA on a 64-MDCT scanner using a low dose (30 mL) of iodixanol 320 and another 50 patients (49 men, one woman; mean age, 65 years) who underwent pulmonary CTA using a regular dose (100 mL) of contrast material during the same time period were selected for review. The 30- and 100-mL pulmonary CTA studies were retrospectively evaluated by two thoracic radiologists in random order. Attenuation values were recorded over the main, right main, selected lobar, segmental, and subsegmental pulmonary arteries. Image quality was also subjectively assessed using visual scores on a scale from 1 (nondiagnostic) to 5 (excellent). RESULTS. The average attenuation measurements of the main, right main, selected lobar, segmental, and subsegmental pulmonary arteries were 260, 262, 280, 316, and 338 HU, respectively, on the 30-mL studies and 313, 301, 316, 344, and 349 HU, respectively, on the 100-mL studies. The average visual score was 4.0 for both the 30- and 100-mL groups. A visual score of 4 or 5 was given to 82% of studies in the 30-mL group and 78% of studies in the 100-mL group. CONCLUSION. Contrast agent dose for pulmonary CTA using a 64-MDCT scanner can be significantly reduced without compromising diagnostic image quality.
机译:目的。我们研究的目的是确定在装有30 mL IV造影剂的64-MDCT扫描仪上进行的肺部CT血管造影(CTA)中是否可以保留血管增强和图像质量。材料和方法。这项回顾性队列研究比较了使用30 mL静脉造影剂与100 mL静脉造影剂进行肺部CTA的图像质量。 50例患者(46名男性,四名女性;平均年龄66岁)的CT图像在64-MDCT扫描仪上使用低剂量(30 mL)的碘克沙醇320进行了肺部CTA检查,另外50例患者(49名男性,一名女性;选择在同一时间使用常规剂量(100 mL)造影剂进行肺部CTA检查的平均年龄(65岁)进行回顾。 30和100 mL肺部CTA研究由两位胸腔放射科医生以随机顺序进行回顾性评估。在主,右主,选定的大叶,节段和节段性肺动脉上记录衰减值。还使用从1(非诊断)到5(优秀)的视觉评分来主观评估图像质量。结果。在30 mL研究中,主,右主干,选定的大叶,节段性和节段性肺动脉的平均衰减量分别为260、262、280、316和338 HU,以及313、301、316、344, 100毫升研究分别为349 HU和349 HU。 30和100 mL组的平均视觉评分均为4.0。 30毫升组中82%的研究和100毫升组中78%的研究给予4或5的视觉评分。结论。使用64-MDCT扫描仪可显着降低肺部CTA的造影剂剂量,而不会影响诊断图像的质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号