OBJECTIVE: Hyperplastic polyps are more difficult to detect than adenomatous polyps at CT colonography (CTC), and it has been theorized that this difference in detectability is because hyperplastic polyps are flatter. Using automated software that computes polyp height, we determined whether hyperplastic colonic polyps on CTC are indeed flatter than adenomatous polyps of comparable width. MATERIALS AND METHODS: At three medical centers, 1,186 patients underwent oral contrast-enhanced CTC and same-day optical colonoscopy (OC) with segment unblinding for colorectal cancer screening. One hundred eighty-five of the patients had at least one hyperplastic or adenomatous polyp 6-10 mm visible at both OC and CTC, where size was determined by a calibrated guidewire at OC. To assess flatness, the heights of the polyps at CTC were measured using a validated automated software program. The heights and height-to-width ratios of the hyperplastic polyps were compared with those of the adenomatous polyps using a Student's t test (two-tailed, unpaired, unequal variance). RESULTS: There were 176 adenomatous and 83 hyperplastic polyps visible at segment-unblinded OC. The fraction of these polyps that were measurable at CTC using the automated software was not significantly different for adenomatous versus hyperplastic polyps (158/176 [89.8%] vs 73/87 [83.9%], respectively; p = 0.2). The average height-to-width ratios using automated width measurements were 15% less for hyperplastic polyps: 0.39 +/- 0.20 (n = 158) and 0.33 +/- 0.19 (n = 73) for adenomatous and hyperplastic polyps, respectively (p = 0.03). When polyps of comparable OC size or CTC width were considered, the heights of hyperplastic polyps were up to 27% less than those of adenomatous polyps. CONCLUSION: For 6-10 mm polyps of a given size as determined by OC or a given width at CTC, hyperplastic polyps tend to be flatter (i.e., have lower height) compared with adenomatous polyps.
机译:目的:增生性息肉比CT结肠造影(CTC)的腺瘤性息肉更难检测,并且理论上说,这种可检测性的差异是因为增生性息肉更扁平。使用自动计算息肉高度的软件,我们确定了CTC上的增生性结肠息肉是否确实比相当宽度的腺瘤性息肉平坦。材料与方法:在三个医疗中心,对1,186例患者进行了口服造影剂增强CTC和当日光学结肠镜检查(OC),并进行了部分盲区的大肠癌筛查。 185名患者在OC和CTC处均可见至少一个增生性或腺瘤性息肉6-10 mm,其大小由OC处的校准导丝确定。为了评估平坦度,使用经过验证的自动化软件程序测量CTC处息肉的高度。使用学生t检验(两尾,不成对,不等方差)比较增生性息肉的高度和高宽比与腺瘤性息肉的高度和高宽比。结果:在无节段的OC中可见176个腺瘤和83个增生性息肉。对于腺瘤性息肉与增生性息肉,使用自动化软件可在CTC处测量的这些息肉比例无显着差异(分别为158/176 [89.8%]与73/87 [83.9%]; p = 0.2)。使用增生性息肉使用自动宽度测量的平均身高比低15%:腺瘤性和增生性息肉分别为0.39 +/- 0.20(n = 158)和0.33 +/- 0.19(n = 73)(p = 0.03)。当考虑到OC大小或CTC宽度相当的息肉时,增生性息肉的高度比腺瘤性息肉的高度低27%。结论:对于由OC确定的给定大小或在CTC处给定宽度的6-10 mm息肉,与腺瘤性息肉相比,增生性息肉趋于平坦(即,高度较低)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号