Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates.

机译:双源CT用于高心率心脏移植患者冠状动脉的可视化。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The purpose of this study was to evaluate the quality of dual-source CT images of the coronary arteries in heart transplant recipients with high heart rates. SUBJECTS AND METHODS: Contrast-enhanced dual-source CT coronary angiography was performed on 23 heart transplant recipients (20 men, three women; mean age, 61.1 +/- 12.8 years). Data sets were reconstructed in 5% steps from 30% to 80% of the R-R interval. Two blinded independent readers using a 5-point scale (0, not evaluative; 4, excellent quality) assessed the quality of images of coronary segments. RESULTS: The mean heart rate during scanning was 89.2 +/- 10.4 beats/min. Interobserver agreement on the quality of images of the whole coronary tree was a kappa value of 0.78 and for selection of the optimal reconstruction interval was a kappa value of 0.82. The optimal reconstruction interval was systole in 17 (74%) of the 23 of heart transplant recipients. At the best reconstruction interval, diagnostic image quality (score or= 2) was obtained in 92.1% (303 of 329) of the coronary artery segments. The mean image quality score for the whole coronary tree was 3.1 +/- 1.01. No significant correlation between mean heart rate (rho = 0.31) or heart rate variability (rho = 0.23) and overall image quality score was observed (p = not significant). CONCLUSION: Dual-source CT acquisition yields coronary angiograms of diagnostic quality in heart transplant recipients. Mean heart rate and heart rate variability during scanning do not have a negative effect on the overall quality of images of the coronary arteries.
机译:目的:本研究旨在评估高心率心脏移植受者冠状动脉双源CT图像的质量。研究对象和方法:对23位心脏移植受者(20名男性,3名女性;平均年龄61.1 +/- 12.8岁)进行了对比增强的双源CT冠状动脉造影。从R-R间隔的30%到80%以5%的步长重建数据集。两个盲人的独立阅读器使用5分制(0分,未评估; 4分,质量出色)评估了冠状动脉段图像的质量。结果:扫描期间的平均心率是89.2 +/- 10.4次/分钟。观察者之间对整个冠状树图像质量的一致意见是kappa值为0.78,而选择最佳重建间隔的kappa值则为0.82。最佳的重建间隔是心脏移植受者中23位接受者中的17位(74%)的收缩期。在最佳重建间隔内,在92.1%(329的303个)冠状动脉节段中获得诊断图像质量(得分>或= 2)。整个冠状树的平均图像质量得分为3.1 +/- 1.01。在平均心率(rho = 0.31)或心率变异性(rho = 0.23)与总体图像质量得分之间未发现显着相关性(p =不显着)。结论:双源CT采集可得出心脏移植接受者的诊断质量的冠状动脉血管造影照片。扫描期间的平均心率和心率变异性对冠状动脉图像的整体质量没有负面影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号