首页> 外文期刊>The Journal of foot and ankle surgery: official publication of the American College of Foot and Ankle Surgeons >Synovial Metallosis After Ceramic Total Ankle Arthroplasty Treated With a Total Talar Prosthesis: A Case Report
【24h】

Synovial Metallosis After Ceramic Total Ankle Arthroplasty Treated With a Total Talar Prosthesis: A Case Report

机译:陶瓷总踝关节成形术治疗的陶瓷总踝关节术治疗的滑膜金属异位:案例报告

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Total ankle arthroplasty is a useful surgical procedure for osteoarthritis of the ankle, but aseptic loosening of components is an issue. We report here a case of aseptic implant loosening with metallosis after total ankle arthroplasty using the TNK ankle (Kyocera, Kyoto, Japan), which occurred despite the components being ceramic. We also report favorable results from our method of treatment using a total talar prosthesis in the revision surgery. During the revision surgery, synovial metallosis was found, probably related to superficial damage to the screw affixing the tibial component to the bone. Because both the tibial and talar components were loose, all the components and the remaining talar bone were removed. A new tibial component and a custom-made alumina-ceramic total talar prosthesis was inserted. Pain relief was achieved and maintained through the latest follow-up visit at 42 months after revision surgery. Dorsiflexion of the ankle improved from 0 degrees to 5 degrees and plantarflexion remained unchanged from its preoperative range of 20 degrees. The American Orthopaedic Foot & Ankle Society ankle-hindfoot score improved from 38 to 80 points. To the best of our knowledge, this is the first reported case of an aluminaceramic total ankle prosthesis loosening caused by metallosis resulting from screw abrasion. Favorable treatment results were obtained by using a total talar prosthesis in the revision surgery. (C) 2019 by the American College of Foot and Ankle Surgeons. All rights reserved.
机译:总踝关节关节造身术是踝关节骨关节炎的一种有用的手术程序,但组件的无菌松动是一个问题。我们在此报告了使用TNK脚踝(Kyocera,Kyoto,Japan)在总踝关节置换术后的无菌植入物松弛,尽管部件是陶瓷的,但仍发生了这种情况。我们还报告了我们在修订手术中使用总缩略图的治疗方法的良好结果。在修订手术期间,发现滑膜金属异位,与粘附胫骨部件粘附到骨骼的螺杆的浅表损伤可能有关。因为胫骨和缩略组分都松动,所以所有组分和剩余的缩略骨都被除去。插入新的胫骨部件和定制的氧化铝 - 陶瓷总缩略图。通过修改手术后42个月的最新后续访问实现和维护疼痛缓解。从0度到5度提高的踝关节的背屈,并且Plantarflexion从其术前范围内保持不变。美国矫形脚和脚踝社会脚踝 - 后足成绩从38到80分。据我们所知,这是由螺杆磨损引起的金属异常引起的第一个据报道的铝制抗体总踝伪空展出的病例。通过在修复手术中使用总缩略图来获得有利的治疗结果。 (c)2019年由美国脚和踝外科医生。版权所有。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号