首页> 外文期刊>PDA journal of pharmaceutical science and technology >Identifying and Mitigating Errors in Screening for Organic Extractables and Leachables: Part 1—Introduction to Errors in Chromatographic Screening for Organic Extractables and Leachables and Discussion of the Errors of Omission
【24h】

Identifying and Mitigating Errors in Screening for Organic Extractables and Leachables: Part 1—Introduction to Errors in Chromatographic Screening for Organic Extractables and Leachables and Discussion of the Errors of Omission

机译:识别和减轻筛选有机萃取物和鹿的误差:第1部分 - 用于有机萃取物和鹿的色谱筛查误差引入,以及遗漏误差的讨论

获取原文
获取原文并翻译 | 示例
           

摘要

Substances leached from materials used in pharmaceutical manufacturing systems, packages, and/or medical devices can be administered to a patient as part of a clinical therapy. These leachables can have an undesirable effect on the effectiveness of the therapy and/or patient safety. Thus, relevant samples such as material extracts or drug products are chromatographically screened for foreign organic impurities, where screening is the analytical process of discovering, identifying, and quantifying these unspecified foreign impurities. Although screening methods for organic extractables and leachables have achieved a high degree of technical and practical sophistication, they are not without issues with respect to their ability to accomplish the aforementioned three functions. In this first part of a series of three manuscripts, the process of screening is examined, limitations in screening are identified, and the concept of using an internally developed analytical database to identify, mitigate, or correct these errors is introduced. Furthermore, errors of omission are described, where an error of omission occurs when a screening method fails to produce a recognizable response to an analyte present in the test sample. The error may be that no response is produced (“falling through the cracks”) or that a produced response is not recognizable (“failing to see the tree for the forest”). In either case, proper use of a robust internal extractables/leachables database can decrease the frequency with which errors of omission occur. Examples of omission errors, their causes, and their possible resolution are discussed.
机译:从药物制造系统,包装和/或医疗装置中使用的材料浸出的物质可以作为临床治疗的一部分给予患者。这些鹿可对治疗和/或患者安全的有效性产生不希望的影响。因此,如材料提取物或药物产品如材料提取物或药物产品用于对外有机杂质进行色谱筛选,其中筛选是发现,鉴定和量化这些未指明的外杂物的分析过程。虽然有机萃取物和浸出物的筛查方法已经实现了高度的技术和实践复杂性,但它们并非没有关于它们完成上述三个功能的能力的问题。在这一系列三种手稿的第一部分中,介绍了筛选过程,介绍了筛选的限制,并介绍了使用内部开发的分析数据库来识别,缓解或校正这些错误的概念。此外,描述了遗漏的错误,其中当筛选方法未能产生对测试样本中存在的分析物的识别响应时发生的遗漏误差。错误可能是没有产生响应(“通过裂缝”)或产生的产生响应不可识别(“未能看到森林树”)。在任何一种情况下,正确使用强大的内部可提取物/ leeachables数据库都可以降低遗漏错误发生的频率。讨论了省略误差,其原因及其可能分辨率的示例。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号