Combined district heating (DH) systems have at least one base load heat plant and several peak-shaving heat sources, which can be installed in the primary network or in the heating substations. This article studies the combined DH system with peak-shaving gas-fired boilers in heating substations, where the peak boilers can be connected to the heat exchangers in series or parallel mode. We analyze the thermal balances for these two connection modes and obtain the analytical operational regulation formulas for them. Then we study the operational methods for each connection mode, considering the heat distribution control strategies in both primary and secondary networks. Adopted control strategies are (1) variable temperature (VT) control, (2) variable flowrate (VF) control, and (3) variable temperature and flowrate (VT-VF) control. The combinations of these three strategies in primary and secondary networks are compared in terms of pumping energy consumption. The results indicate that operational strategies should be phased into different periods according to whether the peak heating is needed or not. In addition, the pumping energy consumption for the parallel connection mode is less than that that for the series connection mode with the same operational strategy, and the VF control strategy shows better energy saving potential.
机译:组合的地区供暖(DH)系统至少有一个基础负载热厂和几个峰值剃须热源,可以安装在主要网络中或加热变电站中。本文研究了在加热变电站中具有峰剃的燃气锅炉的合并DH系统,其中峰值锅炉可以串联或平行模式连接到热交换器。我们分析了这两个连接模式的热余量,并为它们获得分析操作规则公式。然后我们研究每个连接模式的操作方法,考虑主要和次要网络中的热分配控制策略。采用控制策略是(1)可变温度(VT)控制,(2)可变流量(VF)控制,(3)可变温度和流量(VT-VF)控制。在泵送能量消耗方面比较了这三种策略中这三种策略的组合。结果表明,根据需要是否需要峰值加热,应逐步分阶段分阶段分阶段。另外,并联连接模式的泵送能量消耗小于具有相同操作策略的串联连接模式的能耗,并且VF控制策略显示更好的节能潜力。

著录项

  • 来源
  • 作者单位

    Dalian Univ Technol Inst Bldg Environm &

    Facil Engn Sch Civil Engn Dalian 116024 Peoples R China;

    Dalian Univ Technol Inst Bldg Environm &

    Facil Engn Sch Civil Engn Dalian 116024 Peoples R China;

    Dalian Univ Technol Inst Bldg Environm &

    Facil Engn Sch Civil Engn Dalian 116024 Peoples R China;

    Dalian Univ Technol Inst Bldg Environm &

    Facil Engn Sch Civil Engn Dalian 116024 Peoples R China;

    Aalto Univ Sch Engn Dept Mech Engn POB 14100 FI-00076 Aalto Finland;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 建筑基础科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号