As one of the substitutes for R134a in chillers, the refrigeration performance of R450A is poor. Heat exchanger structural improvement is proposed to improve its refrigeration performance in chillers. In this article, the heat transfer characteristics, resistance characteristics, and stress characteristics of shell-and-tube heat exchangers (STHXs) with different baffles (segmental baffles [SB], plane helical baffles [PB], fold helical baffles [FB]) are numerically investigated based on the fluid-solid coupling. The results show that the shell-side flow velocity and temperature difference of STHXsSB are the highest, and those of STHXsPB are the lowest. The heat transfer coefficient and pressure drop of STHXs increase gradually with the increase of the shell-side volume flow, but h/P decreases gradually. Compared with h/P of STHXsSB, that of STHXsPB increases by 62.2-65.7%, and that of STHXsFB increases by 73.9-76.1%. The stresses around the holes of the baffles are higher than other parts of the baffles. Besides, the effect of temperature on the baffle stress distribution is much greater than that of pressure. Although the maximum stress of STHXsFB is the highest, it is in the allowable stress range of the material. Hence, STHXsFB is suitable for water chillers due to its excellent comprehensive performance.
机译:作为冷却器中R134a的替代品之一,R450a的制冷性能差。提出了热交换器结构改进,以改善冷却器中的制冷性能。在本文中,具有不同挡板的壳管热交换器(STHXS)的传热特性,电阻特性和应力特性(分段挡板[SB],平面螺旋挡板[PB],折叠螺旋挡板[FB])基于流体固耦合进行数值研究。结果表明,STHXSSB的壳侧流速和温差最高,STHXSPB的壳体差异最低。随着壳侧体积流量的增加,STHXS的传热系数和压力降逐渐增加,但H / P逐渐降低。与STHXSSB的H / P相比,STHXSPB的H / P增加了62.2-65.7%,STHXSFB的增加73.9-76.1%。挡板孔周围的应力高于挡板的其他部分。此外,温度对挡板应力分布的影响远大于压力。尽管STHXSFB的最大应力是最高的,但它处于材料的允许应力范围内。因此,由于其出色的综合性能,STHXSFB适用于水冷硼。

著录项

  • 来源
  • 作者单位

    Xi An Jiao Tong Univ Sch Energy &

    Power Engn Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Energy &

    Power Engn Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Energy &

    Power Engn Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Energy &

    Power Engn Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Energy &

    Power Engn Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Energy &

    Power Engn Xian Shaanxi Peoples R China;

    Xi An Jiao Tong Univ Sch Energy &

    Power Engn Xian Shaanxi Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 建筑基础科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号