首页> 外文期刊>Gait & posture >Prediction of walk-to-run transition using stride frequency: A test-retest reliability study
【24h】

Prediction of walk-to-run transition using stride frequency: A test-retest reliability study

机译:使用步幅频率预测步行过渡:测试 - 保持可靠性研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The transition from walking to running has previously been predicted to occur at a point where the stride frequency starts getting closer to the running attractor than to the walking attractor. The two behavioural attractors were considered to be represented by the freely chosen stride frequencies during unrestricted treadmill walking and running. The aim of the present study was to determine the relative and absolute test-retest reliability of the predicted walk-to-run transition stride frequency. Healthy individuals (n = 25) performed walking and running on a treadmill in a day-to-day test-retest design. The two behavioral attractors were determined during walking and running at freely chosen velocities and stride frequencies. Subsequently, the walk-to-run transition stride frequency was predicted using camera recordings and a previously reported equation for prediction. The walk-to-run transition occurred at a velocity of 7.7 +/- 0.5 km h(-1) at day 1 as well as at day 2. Besides, the predicted walk-to-run transition stride frequencies were 69.7 +/- 3.3 strides min(-1) and 70.5 +/- 3.4 strides min-1 on day 1 and day 2, respectively (p = 0.08). A further comparison between the predicted walk-to-run transition stride frequencies at day 1 and day 2 showed an ICC3,1 of 0.89, which indicated almost perfect relative reliability. The absolute reliability was reflected by a%-value of the standard error of the measurement (SEM%) of 1.6% and a%-value of the smallest real difference (SRD%) of 4.4%. In conclusion, the predicted walk-to-run transition stride frequency can be considered reliable across days.
机译:从步行到运行的过渡之前已经预测发生在步幅开始越来越接近运行吸引子而不是行走吸引子。两种行为吸引子被认为是由无限制的跑步机行走和运行期间自由选择的步伐频率表示。本研究的目的是确定预测的步行转变潮流频率的相对和绝对的测试 - 保持可靠性。在日常测试 - 重新测试的设计中,在跑步机上行走和运行健康个体(n = 25)。在自由选择的速度下行走和运行期间确定两个行为吸引子。随后,使用摄像机录制预测步行到运行的转变频率和先前报告的预测方程。步行过渡发生在第1天的7.7 +/- 0.5 km H(-1)的速度以及第2天。此外,预测的步行过渡步幅频率为69.7 +/- 3.3分别在第1天和第2天(P = 0.08)时,分别进入min(-1)和70.5 +/- 3.4升高-1。第1天和第2天预测的步行转变频率之间的进一步比较显示了0.89的ICC3,1,这表明了几乎完美的相对可靠性。绝对可靠性反映的是测量标准误差的% - 值为1.6%的标准误差,%-Value的差异最小(SRD%)为4.4%。总之,预测的步行过渡步幅频率可以被认为是可靠的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号