首页> 外文期刊>European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society >Dose, image quality and spine modeling assessment of biplanar EOS micro-dose radiographs for the follow-up of in-brace adolescent idiopathic scoliosis patients
【24h】

Dose, image quality and spine modeling assessment of biplanar EOS micro-dose radiographs for the follow-up of in-brace adolescent idiopathic scoliosis patients

机译:双层EOS微量剂量射线照片的剂量,图像质量和脊柱模拟评估,用于支撑携带型青春期特发性脊柱病患者的后续患者

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose The aim of this study was to compare the radiation dose, image quality and 3D spine parameter measurements of EOS low-dose and micro-dose protocols for in-brace adolescent idiopathic scoliosis (AIS) patients. Methods We prospectively included 25 consecutive patients (20 females, 5 males) followed for AIS and undergoing brace treatment. The mean age was 12?years (SD 2?years, range 8–15?years). For each patient, in-brace biplanar EOS radiographs were acquired in a standing position using both the conventional low-dose and micro-dose protocols. Dose area product (DAP) was systematically recorded. Diagnostic image quality was qualitatively assessed by two radiologists for visibility of anatomical structures. The reliability of 3D spine modeling between two operators was quantitatively evaluated for the most clinically relevant 3D radiological parameters using intraclass correlation coefficient (ICC). Results The mean DAP for the posteroanterior and lateral acquisitions was 300?±?134 and 433?±?181?mGy?cm_(2)for the low-dose radiographs, and 41?±?19 and 81?±?39?mGy?cm_(2)for micro-dose radiographs. Image quality was lower with the micro-dose protocol. The agreement was “good” to “very good” for all measured clinical parameters when comparing the low-dose and micro-dose protocols (ICC?>?0.73). Conclusion The micro-dose protocol substantially reduced the delivered dose (by a factor of 5–7 compared to the low-dose protocol) in braced children with AIS. Although image quality was reduced, the micro-dose protocol proved to be adapted to radiological follow-up, with adequate image quality and reliable clinical measurements. Graphical abstract These slides can be retrieved under Electronic Supplementary Material.
机译:目的本研究的目的是将EOS低剂量和微量剂量方案的辐射剂量,图像质量和3D脊柱参数测量进行比较,用于支撑携带的青少年特发性脊柱侧凸(AIS)患者。方法我们正前瞻性地包括25例患者(20名女性,5名男性),然后进行AIS和接受支架治疗。平均年龄为12岁?年(SD 2?年,8-15岁)。对于每位患者,使用常规的低剂量和微量剂量方案在站立位置获得括号二玻璃射射线照片。系统地记录剂量区域产品(DAP)。两个放射科医师的诊断图像质量因解剖结构的可见性而定性评估。使用脑内相关系数(ICC)定量地评估两个操作员之间的3D脊柱建模的可靠性。结果后肛门和横向采集的平均dap是300?±134和433?±181?mgy?cm_(2),用于低剂量射线照片,41?±19和81?±39?mgy ?CM_(2)用于微量剂量射线照片。微量剂量方案,图像质量较低。在比较低剂量和微量剂量方案(ICC?> 0.73)时,该协议对于所有测量的临床参数,“很好”。结论微量剂量方案基本上将递送剂量减少(与低剂量方案相比的递增剂量为AIS。虽然图像质量降低,但经过微量剂量协议被证明适应放射动态随访,具有足够的图像质量和可靠的临床测量。图形摘要这些幻灯片可以在电子补充材料下检索。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号